Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
129
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0246 # 04 Y:1995 | 04 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,340 | $0 | Not Implemented |
AM0246 # 05 Y:1995 | 05 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,210 | $0 | Not Implemented |
AM0246 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $950 | $0 | Implemented |
AM0246 # 07 Y:1995 | 07 | 1995 | USE SYNTHETIC LUBRICANT | $456 | $0 | Not Implemented |
AM0246 # 08 Y:1995 | 08 | 1995 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $300 | $0 | Not Implemented |
AM0107 # 01 Y:1991 | 01 | 1991 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $12,100 | $0 | Implemented |
AM0107 # 02 Y:1991 | 02 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,000 | $400 | Implemented |
AM0107 # 03 Y:1991 | 03 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $438 | $2,272 | Implemented |
AM0107 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,730 | $2,400 | Implemented |
AM0107 # 05 Y:1991 | 05 | 1991 | INSTALL SET-BACK TIMERS | $750 | $260 | Implemented |
AM0107 # 06 Y:1991 | 06 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $650 | $0 | Implemented |
AM0107 # 07 Y:1991 | 07 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $405 | $130 | Implemented |
AM0026 # 01 Y:1988 | 01 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $867 | $2,000 | Implemented |
AM0026 # 02 Y:1988 | 02 | 1988 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $8,053 | $1,075 | Implemented |
AM0026 # 03 Y:1988 | 03 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,962 | $10,000 | Not Implemented |
AM0026 # 04 Y:1988 | 04 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $851 | $300 | Implemented |
AM0026 # 05 Y:1988 | 05 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $492 | $123 | Not Implemented |
AM0026 # 06 Y:1988 | 06 | 1988 | INSULATE BARE EQUIPMENT | $182 | $114 | Not Implemented |
AM0004 # 01 Y:1987 | 01 | 1987 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,995 | $0 | Implemented |
AM0004 # 02 Y:1987 | 02 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $151 | $107 | Implemented |
AM0004 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,143 | $2,367 | Implemented |
AM0004 # 04 Y:1987 | 04 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $97 | $80 | Implemented |
AM0004 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $595 | $3,500 | Not Implemented |
AM0004 # 06 Y:1987 | 06 | 1987 | INSTALL SET-BACK TIMERS | $97 | $0 | Not Implemented |
AM0004 # 07 Y:1987 | 07 | 1987 | INSTALL SET-BACK TIMERS | $421 | $0 | Not Implemented |