Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

14

matching recommendations
Reset
SIC 371 Motor Vehicles And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0025 # 01 Y:1981 01 1981 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $169 $100 Implemented
KU0025 # 02 Y:1981 02 1981 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $1,267 $1,200 Not Implemented
KU0025 # 03 Y:1981 03 1981 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $992 $0 Not Implemented
KU0025 # 04 Y:1981 04 1981 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $685 $2,076 Not Implemented
KU0025 # 05 Y:1981 05 1981 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,689 $3,748 Implemented
KU0027 # 01 Y:1981 01 1981 INSTALL AUTOMATIC STACK DAMPER $1,605 $1,800 Not Implemented
KU0027 # 02 Y:1981 02 1981 INSTALL TIMERS AND/OR THERMOSTATS $5,685 $1,600 Not Implemented
KU0027 # 03 Y:1981 03 1981 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $700 $0 Not Implemented
KU0027 # 04 Y:1981 04 1981 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $405 $100 Not Implemented
KU0027 # 05 Y:1981 05 1981 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $200 $0 Not Implemented
KU0027 # 06 Y:1981 06 1981 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $160 $300 Not Implemented
KU0027 # 07 Y:1981 07 1981 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $185 $0 Not Implemented
KU0027 # 08 Y:1981 08 1981 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,845 $0 Not Implemented
KU0027 # 09 Y:1981 09 1981 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,720 $5,466 Not Implemented