Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
40
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0146 # 01 Y:1984 | 01 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,620 | $0 | Implemented |
UD0146 # 02 Y:1984 | 02 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $598 | $210 | Implemented |
UD0142 # 02 Y:1984 | 02 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,060 | $10,000 | Implemented |
UD0142 # 03 Y:1984 | 03 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,810 | $384 | Implemented |
UD0142 # 01 Y:1984 | 01 | 1984 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $28,921 | $935 | Implemented |
CO0010 # 02 Y:1984 | 02 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $472 | $500 | Not Implemented |
GT0227 # 06 Y:1984 | 06 | 1984 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $720 | $1,400 | Not Implemented |
GT0227 # 05 Y:1984 | 05 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $850 | $2,858 | Implemented |
GT0227 # 04 Y:1984 | 04 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $193 | $10,600 | Implemented |
GT0227 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,015 | $216 | Implemented |
GT0227 # 02 Y:1984 | 02 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,520 | $1,000 | Not Implemented |
GT0227 # 01 Y:1984 | 01 | 1984 | INSULATE BARE EQUIPMENT | $470 | $300 | Not Implemented |
CO0010 # 11 Y:1984 | 11 | 1984 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $6,677 | $5,000 | Not Implemented |
CO0010 # 10 Y:1984 | 10 | 1984 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $769 | $130 | Implemented |
CO0010 # 09 Y:1984 | 09 | 1984 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $186 | $175 | Implemented |
CO0010 # 08 Y:1984 | 08 | 1984 | UPGRADE OBSOLETE EQUIPMENT | $318 | $30 | Implemented |
CO0010 # 07 Y:1984 | 07 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $165 | $200 | Implemented |
CO0010 # 06 Y:1984 | 06 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $372 | $800 | Implemented |
CO0010 # 05 Y:1984 | 05 | 1984 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $543 | $493 | Not Implemented |
CO0010 # 04 Y:1984 | 04 | 1984 | INSULATE BARE EQUIPMENT | $182 | $68 | Implemented |
CO0010 # 03 Y:1984 | 03 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,168 | $6,000 | Not Implemented |
CO0010 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,635 | $0 | Implemented |
OK0151 # 04 Y:1984 | 04 | 1984 | AIR CONDITION ONLY SPACE NECESSARY | $334 | $0 | Implemented |
OK0151 # 03 Y:1984 | 03 | 1984 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $141 | $336 | Implemented |
OK0151 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $58 | $48 | Implemented |