Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

46

matching recommendations
Reset
SIC 371 Motor Vehicles And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0211 # 12 Y:1986 12 1986 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $990 $0 Implemented
KU0211 # 11 Y:1986 11 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,456 $0 Implemented
KU0211 # 10 Y:1986 10 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,750 $3,236 Not Implemented
KU0211 # 09 Y:1986 09 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,489 $315 Implemented
KU0211 # 08 Y:1986 08 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,559 $525 Not Implemented
KU0211 # 07 Y:1986 07 1986 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $3,369 $4,000 Not Implemented
KU0211 # 06 Y:1986 06 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,890 $5,585 Implemented
KU0211 # 05 Y:1986 05 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $8,125 $6,000 Implemented
KU0211 # 04 Y:1986 04 1986 IMPROVE LUBRICATION PRACTICES $9,940 $10,352 Not Implemented
KU0211 # 03 Y:1986 03 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $11,057 $5,000 Implemented
KU0211 # 02 Y:1986 02 1986 OPTIMIZE PLANT POWER FACTOR $18,000 $30,000 Not Implemented
KU0211 # 01 Y:1986 01 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $35,188 $27,000 Not Implemented
LT0074 # 01 Y:1986 01 1986 COVER OPEN TANKS $1,590 $385 Implemented
TN0286 # 03 Y:1986 03 1986 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,478 $0 Implemented
LT0074 # 06 Y:1986 06 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,425 $1,200 Implemented
TN0286 # 02 Y:1986 02 1986 INSTALL TIMERS AND/OR THERMOSTATS $2,353 $1,315 Not Implemented
TN0286 # 01 Y:1986 01 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $6,868 $2,430 Not Implemented
LT0074 # 02 Y:1986 02 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,114 $1,191 Not Implemented
LT0074 # 04 Y:1986 04 1986 UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS $217 $450 Implemented
LT0074 # 05 Y:1986 05 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,320 $9,000 Not Implemented
LT0074 # 03 Y:1986 03 1986 INSTALL TIMERS AND/OR THERMOSTATS $619 $220 Implemented
TN0286 # 07 Y:1986 07 1986 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $744 $300 Implemented
TN0286 # 04 Y:1986 04 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,097 $3,500 Implemented
TN0286 # 05 Y:1986 05 1986 HEAT WATER WITH EXHAUST HEAT $875 $3,900 Not Implemented
TN0286 # 06 Y:1986 06 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,285 $615 Implemented