Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,792

matching recommendations
Reset
SIC 3714 Motor Vehicle Parts And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0002 # 04 Y:1991 04 1991 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,727 $100 Implemented
IA0002 # 05 Y:1991 05 1991 USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS $527 $0 Implemented
IA0002 # 06 Y:1991 06 1991 INSTALL TIMERS AND/OR THERMOSTATS $446 $300 Implemented
IA0002 # 07 Y:1991 07 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $141 $261 Implemented
IA0002 # 08 Y:1991 08 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $230 $50 Implemented
OK0337 # 01 Y:1991 01 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $59,130 $29,025 Implemented
OK0337 # 02 Y:1991 02 1991 INSULATE BARE EQUIPMENT $24,414 $1,184 Implemented
OK0337 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,667 $0 Implemented
OK0337 # 04 Y:1991 04 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $758 $0 Implemented
OK0337 # 05 Y:1991 05 1991 INSTALL TIMERS AND/OR THERMOSTATS $43,178 $4,650 Implemented
OK0337 # 06 Y:1991 06 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $51,940 $0 Implemented
OK0337 # 07 Y:1991 07 1991 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $26,537 $26,342 Implemented
TN0421 # 01 Y:1991 01 1991 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $30,358 $17,288 Implemented
TN0421 # 02 Y:1991 02 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,865 $390 Implemented
TN0421 # 03 Y:1991 03 1991 CLOSE OFF UNNEEDED STEAM LINES $1,536 $0 Implemented
TN0421 # 04 Y:1991 04 1991 COVER OPEN TANKS $944 $500 Implemented
TN0421 # 05 Y:1991 05 1991 USE MINIMUM STEAM OPERATING PRESSURE $417 $0 Implemented
TN0421 # 06 Y:1991 06 1991 KEEP LAMPS AND REFLECTORS CLEAN $1,855 $5,475 Implemented
TN0421 # 07 Y:1991 07 1991 INSTALL SET-BACK TIMERS $613 $0 Implemented
TN0421 # 08 Y:1991 08 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $553 $490 Implemented
TN0421 # 09 Y:1991 09 1991 TURN OFF EQUIPMENT WHEN NOT IN USE $344 $470 Implemented
UD0336 # 01 Y:1991 01 1991 USE DEMAND CONTROLLER OR LOAD SHEDDER $9,806 $10,000 Implemented
UD0336 # 02 Y:1991 02 1991 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,950 $5,000 Implemented
UD0336 # 03 Y:1991 03 1991 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $8,317 $300 Implemented
UD0336 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $5,078 $0 Implemented