Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,110
matching recommendationsSIC | 3714 | Motor Vehicle Parts And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0309 # 04 Y:1987 | 04 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $20,500 | $95,000 | Implemented |
GT0309 # 05 Y:1987 | 05 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,010 | $8,940 | Implemented |
GT0309 # 06 Y:1987 | 06 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $300 | $150 | Implemented |
GT0309 # 07 Y:1987 | 07 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,285 | $2,056 | Implemented |
KU0211 # 01 Y:1986 | 01 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $35,188 | $27,000 | Not Implemented |
KU0211 # 02 Y:1986 | 02 | 1986 | OPTIMIZE PLANT POWER FACTOR | $18,000 | $30,000 | Not Implemented |
KU0211 # 03 Y:1986 | 03 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $11,057 | $5,000 | Implemented |
KU0211 # 04 Y:1986 | 04 | 1986 | IMPROVE LUBRICATION PRACTICES | $9,940 | $10,352 | Not Implemented |
KU0211 # 05 Y:1986 | 05 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $8,125 | $6,000 | Implemented |
KU0211 # 06 Y:1986 | 06 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,890 | $5,585 | Implemented |
KU0211 # 07 Y:1986 | 07 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $3,369 | $4,000 | Not Implemented |
KU0211 # 08 Y:1986 | 08 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,559 | $525 | Not Implemented |
KU0211 # 09 Y:1986 | 09 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,489 | $315 | Implemented |
KU0211 # 10 Y:1986 | 10 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,750 | $3,236 | Not Implemented |
KU0211 # 11 Y:1986 | 11 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,456 | $0 | Implemented |
KU0211 # 12 Y:1986 | 12 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $990 | $0 | Implemented |
LT0074 # 01 Y:1986 | 01 | 1986 | COVER OPEN TANKS | $1,590 | $385 | Implemented |
LT0074 # 02 Y:1986 | 02 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,114 | $1,191 | Not Implemented |
LT0074 # 03 Y:1986 | 03 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $619 | $220 | Implemented |
LT0074 # 04 Y:1986 | 04 | 1986 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $217 | $450 | Implemented |
LT0074 # 05 Y:1986 | 05 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,320 | $9,000 | Not Implemented |
LT0074 # 06 Y:1986 | 06 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,425 | $1,200 | Implemented |
TN0286 # 01 Y:1986 | 01 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $6,868 | $2,430 | Not Implemented |
TN0286 # 02 Y:1986 | 02 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $2,353 | $1,315 | Not Implemented |
TN0286 # 03 Y:1986 | 03 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,478 | $0 | Implemented |