Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

100

matching recommendations
Reset
SIC 3714 Motor Vehicle Parts And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KS2315 # 06 Y:2023 06 2023 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $39,181 $254,691 Not Implemented
KS2315 # 02 Y:2023 02 2023 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $33,086 $235,752 Implemented
KS2315 # 01 Y:2023 01 2023 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,991 $5,960 Implemented
KS2315 # 03 Y:2023 03 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,175 $24,588 Implemented
KS2315 # 07 Y:2023 07 2023 USE SOLAR HEAT TO MAKE ELECTRICTY $57,874 $421,464 Not Implemented
KS2315 # 04 Y:2023 04 2023 INSTALL OCCUPANCY SENSORS $4,028 $6,350 Implemented
KS2315 # 05 Y:2023 05 2023 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS $545 $1,958 Not Implemented
KS2207 # 02 Y:2022 02 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,721 $18,007 Implemented
KS2207 # 05 Y:2022 05 2022 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,662 $2,460 Not Implemented
KS2207 # 07 Y:2022 07 2022 USE SOLAR HEAT TO MAKE ELECTRICTY $589,910 $5,416,800 Not Implemented
KS2207 # 06 Y:2022 06 2022 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,202 $0 Implemented
KS2207 # 03 Y:2022 03 2022 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,500 $5,480 Not Implemented
KS2207 # 04 Y:2022 04 2022 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $2,371 $2,138 Implemented
KS2207 # 01 Y:2022 01 2022 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $28,812 $1,600 Implemented
KS2204 # 07 Y:2022 07 2022 USE SOLAR HEAT TO MAKE ELECTRICTY $547,827 $3,611,200 Not Implemented
KS2204 # 02 Y:2022 02 2022 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $49,978 $260,052 Not Implemented
KS2204 # 06 Y:2022 06 2022 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,980 $5,480 Not Implemented
KS2204 # 04 Y:2022 04 2022 AIR CONDITION ONLY SPACE NECESSARY $428 $358 Not Implemented
KS2204 # 03 Y:2022 03 2022 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $3,270 $0 Not Implemented
KS2204 # 01 Y:2022 01 2022 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $48,147 $85,515 Not Implemented
KS2204 # 09 Y:2022 09 2022 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $8,396 $1,600 Not Implemented
KS2204 # 08 Y:2022 08 2022 COMBINE UTILITY METERS $3,300 $5,000 Not Implemented
KS2204 # 05 Y:2022 05 2022 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $8,052 $5,134 Not Implemented
GT0956 # 06 Y:2021 06 2021 USE SOLAR HEAT TO MAKE ELECTRICTY $31,203 $419,703 Implemented
GT0956 # 01 Y:2021 01 2021 TURN OFF EQUIPMENT WHEN NOT IN USE $9,326 $300 Not Implemented