Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
271
matching recommendationsSIC | 372 | Aircraft And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0022 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,734 | $100 | Implemented |
LM0022 # 02 Y:2001 | 02 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,848 | $164 | Not Implemented |
LM0022 # 03 Y:2001 | 03 | 2001 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $54,047 | $450 | Implemented |
LM0022 # 04 Y:2001 | 04 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $28,008 | $15,300 | Not Implemented |
LM0022 # 05 Y:2001 | 05 | 2001 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $57,000 | $102,000 | Implemented |
SD0221 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,177 | $3,752 | Implemented |
SD0221 # 02 Y:1999 | 02 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,218 | $3,060 | Not Implemented |
SD0221 # 03 Y:1999 | 03 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $50,303 | $11,995 | Not Implemented |
SD0221 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,107 | $0 | Implemented |
SD0221 # 05 Y:1999 | 05 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,560 | $1,560 | Implemented |
SD0221 # 06 Y:1999 | 06 | 1999 | CONVERT TO AQUEOUS CLEANING SYSTEM | $1,922 | $1,922 | Implemented |
SD0221 # 07 Y:1999 | 07 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,002 | $0 | Implemented |
SD0167 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,037 | $3,300 | Implemented |
SD0167 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,700 | $250 | Implemented |
SD0167 # 03 Y:1997 | 03 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,973 | $6,500 | Implemented |
SD0167 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,304 | $0 | Implemented |
SD0167 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $840 | $0 | Implemented |
SD0167 # 06 Y:1997 | 06 | 1997 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $51,824 | $0 | Not Implemented |
SD0167 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,601 | $24,427 | Implemented |
SD0167 # 08 Y:1997 | 08 | 1997 | BURN A LESS EXPENSIVE GRADE OF FUEL | $12,852 | $0 | Not Implemented |
SD0167 # 09 Y:1997 | 09 | 1997 | MODIFY CURRENT INCENTIVE PROGRAM | $6,790 | $0 | Not Implemented |
SD0185 # 01 Y:1997 | 01 | 1997 | USE OPTIMUM THICKNESS INSULATION | $11,371 | $2,170 | Not Implemented |
SD0185 # 02 Y:1997 | 02 | 1997 | USE OPTIMUM THICKNESS INSULATION | $4,451 | $3,200 | Not Implemented |
SD0185 # 03 Y:1997 | 03 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $1,591 | $1,830 | Not Implemented |
SD0185 # 04 Y:1997 | 04 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $820 | $1,500 | Not Implemented |