Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

72

matching recommendations
Reset
SIC 372 Aircraft And Parts
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0414 # 06 Y:1993 06 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $3,519 $0 Not Implemented
UD0414 # 05 Y:1993 05 1993 INSTALL SET-BACK TIMERS $1,689 $1,500 Implemented
UD0414 # 04 Y:1993 04 1993 INSTALL SET-BACK TIMERS $1,773 $500 Implemented
UD0414 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,246 $14,248 Implemented
UD0414 # 02 Y:1993 02 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $20,700 $20,000 Not Implemented
UD0414 # 01 Y:1993 01 1993 PAY UTILITY BILLS ON TIME $2,100 $0 Implemented
CO0287 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,180 $16,170 Implemented
CO0287 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,770 $7,180 Not Implemented
CO0287 # 03 Y:1993 03 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,360 $2,500 Not Implemented
CO0285 # 08 Y:1993 08 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,540 $1,000 Not Implemented
CO0285 # 10 Y:1993 10 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,290 $2,790 Not Implemented
CO0285 # 09 Y:1993 09 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,470 $3,320 Not Implemented
CO0285 # 03 Y:1993 03 1993 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,720 $8,500 Not Implemented
CO0285 # 01 Y:1993 01 1993 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $92,610 $6,220 Not Implemented
CO0285 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $1,400 $480 Not Implemented
CO0285 # 05 Y:1993 05 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,840 $130 Not Implemented
CO0285 # 02 Y:1993 02 1993 RECOVER WASTE HEAT FROM EQUIPMENT $9,680 $2,010 Not Implemented
CO0285 # 07 Y:1993 07 1993 INSTALL TIMERS AND/OR THERMOSTATS $1,540 $750 Not Implemented
CO0285 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,170 $7,020 Not Implemented
CO0285 # 11 Y:1993 11 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $860 $400 Not Implemented
CO0285 # 12 Y:1993 12 1993 USE POWER DURING OFF-PEAK PERIODS $660 $120 Not Implemented
CO0285 # 13 Y:1993 13 1993 USE PHOTOCELL CONTROLS $310 $560 Not Implemented
AR0008 # 03 Y:1993 03 1993 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $1,379 $1,000 Not Implemented
AR0008 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,102 $130 Implemented
AR0008 # 05 Y:1993 05 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $885 $100 Not Implemented