Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
210
matching recommendationsSIC | 3721 | Aircraft |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0376 # 01 Y:2020 | 01 | 2020 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $234,414 | $800 | Not Implemented |
MI0376 # 02 Y:2020 | 02 | 2020 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $205,000 | $1,013,224 | Not Implemented |
MI0376 # 07 Y:2020 | 07 | 2020 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,944 | $440 | Not Implemented |
MI0376 # 05 Y:2020 | 05 | 2020 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,695 | $5,875 | Not Implemented |
MI0376 # 04 Y:2020 | 04 | 2020 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $25,854 | $580 | Not Implemented |
MI0376 # 08 Y:2020 | 08 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $763 | $289 | Not Implemented |
MI0376 # 03 Y:2020 | 03 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $55,477 | $1,980 | Not Implemented |
MI0376 # 06 Y:2020 | 06 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,838 | $9,120 | Implemented |
SU0411 # 06 Y:2016 | 06 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,579 | $45,826 | Not Implemented |
SU0411 # 04 Y:2016 | 04 | 2016 | ELIMINATE/REDUCE AN OPERATION | $3,627 | $6,660 | Implemented |
SU0411 # 05 Y:2016 | 05 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $167 | $235 | Implemented |
SU0411 # 02 Y:2016 | 02 | 2016 | REDUCE VENTILATION AIR | $3,422 | $10,350 | Implemented |
SU0411 # 01 Y:2016 | 01 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,414 | $0 | Implemented |
SU0411 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,158 | $1,449 | Implemented |
LE0395 # 14 Y:2015 | 14 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,437 | $64,250 | Not Implemented |
LE0395 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $566 | $240 | Not Implemented |
LE0395 # 11 Y:2015 | 11 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,768 | $8,250 | Not Implemented |
LE0395 # 01 Y:2015 | 01 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,054 | $0 | Not Implemented |
LE0395 # 08 Y:2015 | 08 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $19,541 | $18,800 | Not Implemented |
LE0395 # 13 Y:2015 | 13 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,525 | $1,500 | Not Implemented |
LE0395 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $224 | $450 | Not Implemented |
LE0395 # 12 Y:2015 | 12 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $4,108 | $9,000 | Not Implemented |
LE0395 # 09 Y:2015 | 09 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,966 | $3,000 | Not Implemented |
LE0395 # 15 Y:2015 | 15 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,025 | $41,790 | Not Implemented |
LE0395 # 07 Y:2015 | 07 | 2015 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,372 | $1,200 | Not Implemented |