Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
57
matching recommendationsSIC | 3732 | Boat Building And Repairing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0210 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,533 | $1,051 | Not Implemented |
LL0210 # 04 Y:2004 | 04 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,154 | $507 | Not Implemented |
LL0210 # 03 Y:2004 | 03 | 2004 | BURN A LESS EXPENSIVE GRADE OF FUEL | $5,147 | $1,528 | Implemented |
LL0210 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $104,709 | $19,500 | Implemented |
LL0183 # 02 Y:2004 | 02 | 2004 | USE PHOTOCELL CONTROLS | $2,598 | $585 | Not Implemented |
LL0183 # 05 Y:2004 | 05 | 2004 | COMBINE UTILITY METERS | $1,413 | $60 | Not Implemented |
LL0183 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,257 | $600 | Implemented |
LL0183 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,585 | $1,760 | Implemented |
LL0183 # 01 Y:2004 | 01 | 2004 | OPTIMIZE PLANT POWER FACTOR | $9,156 | $14,105 | Not Implemented |
LL0183 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $177 | $50 | Not Implemented |
LT0114 # 09 Y:1988 | 09 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,400 | $450 | Implemented |
LT0114 # 08 Y:1988 | 08 | 1988 | USE RADIANT HEATER FOR SPOT HEATING | $3,500 | $1,860 | Not Implemented |
LT0114 # 07 Y:1988 | 07 | 1988 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $11,900 | $5,500 | Not Implemented |
LT0114 # 06 Y:1988 | 06 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $4,760 | $400 | Not Implemented |
LT0114 # 05 Y:1988 | 05 | 1988 | AIR CONDITION ONLY SPACE NECESSARY | $9,160 | $9,110 | Not Implemented |
LT0114 # 04 Y:1988 | 04 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $378 | $133 | Not Implemented |
LT0114 # 03 Y:1988 | 03 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $777 | $0 | Not Implemented |
LT0114 # 02 Y:1988 | 02 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,670 | $4,560 | Not Implemented |
LT0114 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $757 | $315 | Not Implemented |
LT0089 # 04 Y:1987 | 04 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $447 | $0 | Implemented |
LT0089 # 05 Y:1987 | 05 | 1987 | INSTALL SET-BACK TIMERS | $626 | $0 | Implemented |
LT0089 # 06 Y:1987 | 06 | 1987 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,040 | $3,860 | Implemented |
LT0089 # 07 Y:1987 | 07 | 1987 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $604 | $0 | Implemented |
LT0089 # 03 Y:1987 | 03 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $473 | $612 | Implemented |
LT0089 # 02 Y:1987 | 02 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $1,022 | $388 | Not Implemented |