IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

281

matching recommendations
Reset
SIC 374 Railroad Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0052 # 02 Y:1996 02 1996 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,689 $3,250 Not Implemented
NV0052 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $121 $100 Implemented
NV0052 # 04 Y:1996 04 1996 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $4,914 $0 Implemented
BD0019 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $591 $984 Implemented
BD0019 # 02 Y:1995 02 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,496 $100 Implemented
BD0019 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,217 $7,250 Not Implemented
BD0019 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,182 $1,500 Implemented
WV0031 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $395 $4,126 Implemented
WV0031 # 02 Y:1994 02 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $861 $238 Not Implemented
WV0031 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $49,707 $2,250 Implemented
WV0031 # 04 Y:1994 04 1994 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $5,261 $2,000 Not Implemented
WV0031 # 05 Y:1994 05 1994 INSULATE BARE EQUIPMENT $3,603 $329 Not Implemented
WV0031 # 06 Y:1994 06 1994 USE SYNTHETIC LUBRICANT $14,543 $0 Implemented
WV0031 # 07 Y:1994 07 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $228 $0 Implemented
WI0152 # 01 Y:1992 01 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,294 $29 Not Implemented
WI0152 # 02 Y:1992 02 1992 RECOVER AND REUSE COOLING WATER $11,189 $15 Implemented
WI0152 # 03 Y:1992 03 1992 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $8,842 $0 Not Implemented
WI0152 # 04 Y:1992 04 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,429 $0 Not Implemented
WI0152 # 05 Y:1992 05 1992 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $7,557 $3,000 Implemented
WI0152 # 06 Y:1992 06 1992 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,351 $12,000 Implemented
WI0152 # 07 Y:1992 07 1992 USE RADIANT HEATER FOR SPOT HEATING $9,809 $41,400 Not Implemented
WI0152 # 08 Y:1992 08 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,647 $500 Implemented
WI0152 # 09 Y:1992 09 1992 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $6,814 $0 Implemented
WI0152 # 10 Y:1992 10 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,153 $1,650 Implemented
WI0152 # 11 Y:1992 11 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,832 $0 Not Implemented