IAC logo
IAC Assessment: WI0152
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0152
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1992
Principal Product DOORS, STEAM GENERATORS
NAICS n/a
SIC 3743 - Railroad Equipment
Sales $50,000,000-$100,000,000
# of Employees 450
Plant Area (Sq.Ft.) 0
Annual Production 62,726 Pieces
Production Hrs. Annual 5,300
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $450,415 5,280,188 kWh $0.09
Natural Gas $152,576 57,534 MMBtu $2.65
TOTAL ENERGY COSTS $602,991
RECOMMENDED SAVINGS* $65,744 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $36,538
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,294
Cost:
$29
$6,294 73,857 - - - - $6,294
73,857
kWh
-
-
MMBtu
-
-
$
02: 3.4115 RECOVER AND REUSE COOLING WATER Savings:
$11,189
Cost:
$15
$(-5,620) (-65,944) - - $16,809 - $(-5,620)
(-65,944)
kWh
-
-
MMBtu
$16,809
-
$
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$8,842
Cost:
-
$8,842 - - - - - $8,842
-
kWh
-
-
MMBtu
-
-
$
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,429
Cost:
-
$6,679 - - - $(-4,250) - $6,679
-
kWh
-
-
MMBtu
$(-4,250)
-
$
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$7,557
Cost:
$3,000
$7,419 87,046 $138 52 - - $7,419
87,046
kWh
$138
52
MMBtu
-
-
$
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$2,351
Cost:
$12,000
- - $287 88 $2,064 - -
-
kWh
$287
88
MMBtu
$2,064
-
$
07: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$9,809
Cost:
$41,400
- - $7,465 2,817 $2,344 - -
-
kWh
$7,465
2,817
MMBtu
$2,344
-
$
08: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$5,647
Cost:
$500
- - $5,647 2,131 - - -
-
kWh
$5,647
2,131
MMBtu
-
-
$
09: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$6,814
Cost:
-
- - $6,814 2,571 - - -
-
kWh
$6,814
2,571
MMBtu
-
-
$
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,153
Cost:
$1,650
$2,153 25,205 - - - - $2,153
25,205
kWh
-
-
MMBtu
-
-
$
11: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,832
Cost:
-
$1,832 21,395 - - - - $1,832
21,395
kWh
-
-
MMBtu
-
-
$
12: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$827
Cost:
$2,800
- - $827 312 - - -
-
kWh
$827
312
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$65,744
Cost:
$61,394
$27,599 141,559 $21,178 7,971 $16,967 - $27,599
141,559
kWh
$21,178
7,971
MMBtu
$16,967
-
$
TOTAL IMPLEMENTED Savings:
$36,538
Cost:
$19,965
$3,952 46,307 $13,713 5,154 $18,873 - $3,952
46,307
kWh
$13,713
5,154
MMBtu
$18,873
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes