Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
16
matching recommendationsSIC | 379 | Miscellaneous Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0890 # 01 Y:2013 | 01 | 2013 | BURN A LESS EXPENSIVE GRADE OF FUEL | $544,478 | $0 | Implemented |
UD0890 # 02 Y:2013 | 02 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,847 | $0 | Not Implemented |
UD0890 # 03 Y:2013 | 03 | 2013 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $37,340 | $0 | Implemented |
UD0890 # 04 Y:2013 | 04 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $136,711 | $0 | Implemented |
UD0890 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,587 | $19,427 | Not Implemented |
UD0890 # 06 Y:2013 | 06 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,216 | $0 | Implemented |
UD0890 # 07 Y:2013 | 07 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $37,438 | $6,000 | Implemented |
UD0890 # 08 Y:2013 | 08 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,203 | $0 | Implemented |
UD0890 # 09 Y:2013 | 09 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $176,886 | $101,000 | Not Implemented |
UD0890 # 10 Y:2013 | 10 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $746,973 | $100,000 | Not Implemented |
UD0890 # 11 Y:2013 | 11 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $565,879 | $1,157,500 | Not Implemented |
UD0890 # 12 Y:2013 | 12 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $19,159 | $0 | Not Implemented |
TT0106 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $8,613 | $37,637 | Not Implemented |
TT0106 # 02 Y:2013 | 02 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,063 | $720 | Implemented |
TT0106 # 03 Y:2013 | 03 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,763 | $5,520 | Not Implemented |
TT0106 # 04 Y:2013 | 04 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,586 | $9,280 | Not Implemented |