Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2013 |
Principal Product | Defense Combat Vehicles |
NAICS | 336992 - Military Armored Vehicle, Tank, and Tank Component Manufacturing |
SIC | 3795 - Tanks And Tank Components |
Sales | $100,000,000-$500,000,000 |
# of Employees | 550 |
Plant Area (Sq.Ft.) | 1,600,000 |
Annual Production | 150 Pieces |
Production Hrs. Annual | 2,125 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,061,206 | 46,527,600 | kWh | $0.04 |
Electricity Demand | $1,180,412 | 93,636 | kW-months/year | $12.61 |
Natural Gas | $662,576 | 145,461 | MMBtu | $4.56 |
Coal | $1,272,701 | 200,198 | MMBtu | $6.36 |
TOTAL ENERGY COSTS | $5,176,895 | |||
RECOMMENDED SAVINGS* | $2,288,717 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $767,386 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Coal | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Natural Gas | Coal | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $544,478 Cost: - |
$33,135 | 768,082 | $(-640,879) | (-140,698) | $1,152,222 | 181,247 | - | - | - | - |
$33,135 768,082 kWh |
$(-640,879) (-140,698) MMBtu |
$1,152,222 181,247 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,847 Cost: - |
- | - | $1,847 | 406 | - | - | - | - | - | - |
- - kWh |
$1,847 406 MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8118 CHECK FOR ACCURACY OF UTILITY / POWER METERS |
Savings: $37,340 Cost: - |
- | - | - | - | - | - | - | - | $37,340 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - $ |
$37,340 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $136,711 Cost: - |
$136,711 | 3,169,000 | - | - | - | - | - | - | - | - |
$136,711 3,169,000 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,587 Cost: $19,427 |
$10,009 | 232,016 | - | - | - | - | $578 | - | - | - |
$10,009 232,016 kWh |
- - MMBtu |
- - MMBtu |
$578 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $5,216 Cost: - |
$5,216 | 120,918 | - | - | - | - | - | - | - | - |
$5,216 120,918 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $37,438 Cost: $6,000 |
$7,844 | 181,838 | $29,594 | 5,047 | - | - | - | - | - | - |
$7,844 181,838 kWh |
$29,594 5,047 MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $6,203 Cost: - |
$6,203 | 143,780 | - | - | - | - | - | - | - | - |
$6,203 143,780 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $176,886 Cost: $101,000 |
$176,886 | 4,100,283 | - | - | - | - | - | - | - | - |
$176,886 4,100,283 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $746,973 Cost: $100,000 |
$112,915 | 2,617,416 | $173,812 | 29,661 | $460,246 | 78,540 | - | - | - | - |
$112,915 2,617,416 kWh |
$173,812 29,661 MMBtu |
$460,246 78,540 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $565,879 Cost: $1,157,500 |
- | - | $(-452,279) | (-99,293) | $1,018,158 | 160,158 | - | - | - | - |
- - kWh |
$(-452,279) (-99,293) MMBtu |
$1,018,158 160,158 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $19,159 Cost: - |
$19,159 | 444,119 | - | - | - | - | - | - | - | - |
$19,159 444,119 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $2,288,717 Cost: $1,383,927 |
$508,078 | 11,777,452 | $(-887,905) | (-204,877) | $2,630,626 | 419,945 | $578 | - | $37,340 | - | $508,078 11,777,452 kWh |
$(-887,905) (-204,877) MMBtu |
$2,630,626 419,945 MMBtu |
$578 - $ |
$37,340 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $767,386 Cost: $6,000 |
$189,109 | 4,383,618 | $(-611,285) | (-135,651) | $1,152,222 | 181,247 | - | - | $37,340 | - | $189,109 4,383,618 kWh |
$(-611,285) (-135,651) MMBtu |
$1,152,222 181,247 MMBtu |
- - $ |
$37,340 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Coal | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Natural Gas | Coal | Administrative Changes | One-time Revenue or Avoided Cost |