IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,140

matching recommendations
Reset
SIC 38 Instruments And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0007 # 03 Y:1993 03 1993 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,899 $6,000 Not Implemented
WV0007 # 04 Y:1993 04 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $968 $330 Implemented
WV0007 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $54 $201 Not Implemented
WV0007 # 06 Y:1993 06 1993 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $8,932 $0 Implemented
WV0007 # 07 Y:1993 07 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,481 $1,030 Not Implemented
CO0273 # 01 Y:1993 01 1993 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $5,750 $250 Implemented
CO0273 # 02 Y:1993 02 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,110 $1,200 Implemented
CO0273 # 03 Y:1993 03 1993 RECOVER WASTE HEAT FROM EQUIPMENT $2,510 $2,100 Not Implemented
CO0273 # 04 Y:1993 04 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,260 $2,830 Implemented
CO0273 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $500 $840 Implemented
CO0273 # 06 Y:1993 06 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $610 $1,350 Not Implemented
CO0273 # 07 Y:1993 07 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,580 $3,915 Implemented
SD0058 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,160 $1,207 Implemented
SD0058 # 02 Y:1993 02 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,446 $3,100 Not Implemented
SD0058 # 03 Y:1993 03 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $47,171 $20,975 Not Implemented
SD0058 # 04 Y:1993 04 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $11,510 $0 Implemented
SD0058 # 05 Y:1993 05 1993 SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM $16,800 $11,500 Not Implemented
SD0058 # 06 Y:1993 06 1993 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $12,600 $5,400 Not Implemented
SD0058 # 07 Y:1993 07 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,945 $3,500 Not Implemented
SD0058 # 08 Y:1993 08 1993 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,378 $398 Not Implemented
SD0058 # 09 Y:1993 09 1993 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $332 $0 Not Implemented
SD0058 # 10 Y:1993 10 1993 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $144 $76 Not Implemented
SD0058 # 11 Y:1993 11 1993 COVER OPEN TANKS $299 $417 Not Implemented
SD0058 # 12 Y:1993 12 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,628 $160 Implemented
SD0058 # 13 Y:1993 13 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,259 $40 Implemented