Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,140
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0069 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $4,240 | $0 | Implemented |
AM0069 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,360 | $1,000 | Implemented |
AM0069 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $536 | $116 | Not Implemented |
AM0069 # 06 Y:1989 | 06 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,485 | $2,000 | Not Implemented |
AM0069 # 07 Y:1989 | 07 | 1989 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $1,110 | $4,000 | Not Implemented |
AM0070 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $18,800 | $34,600 | Not Implemented |
AM0070 # 02 Y:1989 | 02 | 1989 | OPTIMIZE PLANT POWER FACTOR | $3,500 | $4,000 | Not Implemented |
AM0070 # 03 Y:1989 | 03 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $175 | $250 | Implemented |
AM0070 # 04 Y:1989 | 04 | 1989 | IMPROVE LUBRICATION PRACTICES | $149 | $0 | Not Implemented |
AM0070 # 05 Y:1989 | 05 | 1989 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $120 | $0 | Implemented |
TN0374 # 01 Y:1989 | 01 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $3,618 | $3,660 | Implemented |
TN0374 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,973 | $840 | Implemented |
TN0374 # 03 Y:1989 | 03 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $4,180 | $9,149 | Not Implemented |
TN0374 # 04 Y:1989 | 04 | 1989 | IMPROVE LUBRICATION PRACTICES | $2,011 | $600 | Implemented |
TN0374 # 05 Y:1989 | 05 | 1989 | INSULATE BARE EQUIPMENT | $1,515 | $704 | Not Implemented |
TN0374 # 06 Y:1989 | 06 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,075 | $350 | Not Implemented |
TN0374 # 07 Y:1989 | 07 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $813 | $1,250 | Implemented |
TN0374 # 08 Y:1989 | 08 | 1989 | INSTALL SET-BACK TIMERS | $675 | $0 | Implemented |
TN0374 # 09 Y:1989 | 09 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $608 | $366 | Implemented |
TN0366 # 01 Y:1989 | 01 | 1989 | USE MINIMUM STEAM OPERATING PRESSURE | $4,924 | $0 | Implemented |
TN0366 # 02 Y:1989 | 02 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $4,213 | $720 | Implemented |
TN0366 # 03 Y:1989 | 03 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,450 | $718 | Implemented |
TN0366 # 04 Y:1989 | 04 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $10,766 | $33,188 | Not Implemented |
TN0366 # 05 Y:1989 | 05 | 1989 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,712 | $4,156 | Implemented |