Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
72
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0162 # 04 Y:2016 | 04 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,605 | $800 | Implemented |
DL0162 # 03 Y:2016 | 03 | 2016 | REDUCE VENTILATION AIR | $2,430 | $340 | Not Implemented |
DL0162 # 02 Y:2016 | 02 | 2016 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,660 | $0 | Implemented |
DL0162 # 01 Y:2016 | 01 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $22,170 | $0 | Implemented |
DL0160 # 06 Y:2016 | 06 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,935 | $211,395 | Implemented |
DL0160 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,525 | $99,395 | Not Implemented |
DL0160 # 04 Y:2016 | 04 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $18,520 | $65,650 | Not Implemented |
DL0160 # 03 Y:2016 | 03 | 2016 | REDUCE VENTILATION AIR | $32,810 | $1,560 | Not Implemented |
DL0160 # 02 Y:2016 | 02 | 2016 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,550 | $0 | Implemented |
DL0160 # 01 Y:2016 | 01 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $25,680 | $0 | Not Implemented |
DL0075 # 03 Y:2011 | 03 | 2011 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $14,910 | $47,500 | Not Implemented |
DL0075 # 01 Y:2011 | 01 | 2011 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $17,900 | $6,660 | Not Implemented |
DL0075 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,400 | $740 | Not Implemented |
DL0075 # 08 Y:2011 | 08 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $719 | $1,100 | Not Implemented |
DL0075 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,281 | $5,000 | Not Implemented |
DL0075 # 06 Y:2011 | 06 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,000 | $5,000 | Not Implemented |
DL0075 # 05 Y:2011 | 05 | 2011 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $6,900 | $9,250 | Not Implemented |
DL0075 # 04 Y:2011 | 04 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $6,900 | $2,920 | Not Implemented |
DL0075 # 02 Y:2011 | 02 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,000 | $10,910 | Not Implemented |
DL0067 # 08 Y:2011 | 08 | 2011 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $19,150 | $13,200 | Not Implemented |
DL0067 # 07 Y:2011 | 07 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,400 | $1,200 | Not Implemented |
DL0067 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $4,518 | $3,100 | Not Implemented |
DL0067 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $9,000 | $1,500 | Not Implemented |
DL0067 # 04 Y:2011 | 04 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,082 | $1,000 | Not Implemented |
DL0067 # 03 Y:2011 | 03 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $331 | $780 | Not Implemented |