Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
109
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0068 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $1,210 | $2,719 | Not Implemented |
UA0068 # 01 Y:2011 | 01 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $16,400 | $5,100 | Implemented |
UA0068 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,210 | $4,238 | Not Implemented |
UA0068 # 05 Y:2011 | 05 | 2011 | DISCONNECT BALLASTS | $3,015 | $607 | Not Implemented |
UA0068 # 02 Y:2011 | 02 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $15,438 | $13,988 | Implemented |
UA0068 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,451 | $46,341 | Implemented |
MA0680 # 01 Y:2011 | 01 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,371 | $45,123 | Implemented |
MA0680 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $151 | $0 | Implemented |
MA0680 # 03 Y:2011 | 03 | 2011 | REDUCE VENTILATION AIR | $630 | $2,895 | Implemented |
MA0680 # 02 Y:2011 | 02 | 2011 | REDUCE VENTILATION AIR | $3,229 | $2,895 | Implemented |
MA0680 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $265 | $2,000 | Not Implemented |
LE0325 # 04 Y:2011 | 04 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,438 | $0 | Not Implemented |
LE0325 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,946 | $6,396 | Implemented |
LE0325 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,815 | $15,840 | Not Implemented |
LE0325 # 02 Y:2011 | 02 | 2011 | USE SOLAR HEAT TO HEAT WATER | $52,419 | $21,000 | Not Implemented |
LE0325 # 01 Y:2011 | 01 | 2011 | USE HEAT PUMP FOR SPACE CONDITIONING | $148,547 | $900,000 | Not Implemented |
LE0325 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,249 | $15,615 | Implemented |
LE0325 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,654 | $1,955 | Not Implemented |
DL0075 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,281 | $5,000 | Not Implemented |
DL0075 # 08 Y:2011 | 08 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $719 | $1,100 | Not Implemented |
DL0075 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,400 | $740 | Not Implemented |
DL0075 # 04 Y:2011 | 04 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $6,900 | $2,920 | Not Implemented |
DL0075 # 03 Y:2011 | 03 | 2011 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $14,910 | $47,500 | Not Implemented |
DL0075 # 02 Y:2011 | 02 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,000 | $10,910 | Not Implemented |
DL0075 # 01 Y:2011 | 01 | 2011 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $17,900 | $6,660 | Not Implemented |