Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

123

matching recommendations
Reset
SIC 382 Measuring And Controlling Devices
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0388 # 02 Y:1997 02 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $970 $400 Implemented
CO0388 # 03 Y:1997 03 1997 RECOVER WASTE HEAT FROM EQUIPMENT $390 $930 Implemented
CO0388 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $390 $330 Implemented
CO0388 # 05 Y:1997 05 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $260 $500 Not Implemented
CO0388 # 06 Y:1997 06 1997 UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID $3,300 $11,100 Not Implemented
CO0388 # 07 Y:1997 07 1997 BURN WASTE OIL FOR HEAT $830 $3,320 Not Implemented
CO0388 # 08 Y:1997 08 1997 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $1,180 $1,500 Not Implemented
CO0388 # 09 Y:1997 09 1997 ELIMINATE/REDUCE REDUNDANT INSPECTIONS $5,910 $14,000 Implemented
CO0221 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,056 $0 Not Implemented
CO0221 # 02 Y:1991 02 1991 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $633 $1,200 Not Implemented
CO0221 # 03 Y:1991 03 1991 INSTALL SET-BACK TIMERS $516 $1,200 Not Implemented
CO0221 # 04 Y:1991 04 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $380 $150 Not Implemented
CO0221 # 05 Y:1991 05 1991 RECOVER WASTE HEAT FROM EQUIPMENT $438 $810 Not Implemented
CO0221 # 06 Y:1991 06 1991 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $1,428 $600 Not Implemented
CO0221 # 07 Y:1991 07 1991 INSTALL TIMERS AND/OR THERMOSTATS $2,100 $4,600 Not Implemented
CO0221 # 08 Y:1991 08 1991 INSTALL AUTOMATIC STACK DAMPER $340 $600 Not Implemented
CO0221 # 09 Y:1991 09 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $217 $487 Not Implemented
CO0124 # 01 Y:1988 01 1988 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $834 $300 Implemented
CO0124 # 02 Y:1988 02 1988 INSTALL TIMERS AND/OR THERMOSTATS $1,162 $0 Implemented
CO0124 # 03 Y:1988 03 1988 AIR CONDITION ONLY SPACE NECESSARY $1,645 $1,000 Implemented
CO0124 # 04 Y:1988 04 1988 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,150 $1,200 Implemented
CO0124 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $881 $969 Implemented
CO0100 # 01 Y:1987 01 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,308 $300 Implemented
CO0100 # 02 Y:1987 02 1987 DIRECT WARMEST AIR TO COMBUSTION INTAKE $242 $450 Not Implemented
CO0100 # 03 Y:1987 03 1987 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $50,411 $138,000 Implemented