Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,032
matching recommendationsSIC | 3841 | Surgical And Medical Instruments |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0342 # 13 Y:2012 | 13 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $72,444 | $410,000 | Implemented |
LE0342 # 14 Y:2012 | 14 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,722 | $85,000 | Implemented |
UA0068 # 01 Y:2011 | 01 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $16,400 | $5,100 | Implemented |
UA0068 # 02 Y:2011 | 02 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $15,438 | $13,988 | Implemented |
UA0068 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,210 | $4,238 | Not Implemented |
UA0068 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,451 | $46,341 | Implemented |
UA0068 # 05 Y:2011 | 05 | 2011 | DISCONNECT BALLASTS | $3,015 | $607 | Not Implemented |
UA0068 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $1,210 | $2,719 | Not Implemented |
LE0325 # 01 Y:2011 | 01 | 2011 | USE HEAT PUMP FOR SPACE CONDITIONING | $148,547 | $900,000 | Not Implemented |
LE0325 # 02 Y:2011 | 02 | 2011 | USE SOLAR HEAT TO HEAT WATER | $52,419 | $21,000 | Not Implemented |
LE0325 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,249 | $15,615 | Implemented |
LE0325 # 04 Y:2011 | 04 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,438 | $0 | Not Implemented |
LE0325 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,946 | $6,396 | Implemented |
LE0325 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,815 | $15,840 | Not Implemented |
LE0325 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,654 | $1,955 | Not Implemented |
MI0208 # 01 Y:2011 | 01 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $40,370 | $292,600 | Implemented |
MI0208 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,143 | $16,918 | Implemented |
MI0208 # 03 Y:2011 | 03 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $25,727 | $48,170 | Implemented |
MI0208 # 04 Y:2011 | 04 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $16,075 | $2,550 | Not Implemented |
MI0208 # 05 Y:2011 | 05 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,241 | $20,530 | Not Implemented |
MI0208 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,355 | $1,320 | Implemented |
MI0208 # 07 Y:2011 | 07 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,789 | $2,400 | Implemented |
MI0207 # 01 Y:2011 | 01 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $123,852 | $137,314 | Not Implemented |
MI0207 # 02 Y:2011 | 02 | 2011 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $76,417 | $150,000 | Not Implemented |
MI0207 # 03 Y:2011 | 03 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $61,926 | $2,550 | Implemented |