IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

997

matching recommendations
Reset
SIC 3841 Surgical And Medical Instruments
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0156 # 01 Y:2003 01 2003 SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE $1,112 $870 Implemented
LE0156 # 02 Y:2003 02 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,320 $750 Not Implemented
LE0156 # 03 Y:2003 03 2003 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $5,466 $0 Not Implemented
LE0156 # 04 Y:2003 04 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,340 $0 Implemented
LE0156 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $1,413 $0 Implemented
LE0156 # 06 Y:2003 06 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $844 $0 Not Implemented
LE0156 # 07 Y:2003 07 2003 INSTALL OCCUPANCY SENSORS $239 $600 Implemented
AM0437 # 01 Y:2003 01 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,100 $0 Implemented
AM0437 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,670 $1,900 Implemented
AM0437 # 03 Y:2003 03 2003 USE SYNTHETIC LUBRICANT $5,500 $0 Not Implemented
AM0437 # 04 Y:2003 04 2003 INSULATE BARE EQUIPMENT $4,480 $1,380 Implemented
AM0437 # 05 Y:2003 05 2003 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $2,110 $0 Implemented
AM0437 # 06 Y:2003 06 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $1,500 $0 Not Implemented
AM0437 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $975 $785 Implemented
AM0437 # 08 Y:2003 08 2003 USE PHOTOCELL CONTROLS $1,110 $110 Implemented
AM0437 # 09 Y:2003 09 2003 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $3,464 $350 Implemented
UU0035 # 01 Y:2002 01 2002 REPAIR OR REPLACE STEAM TRAPS $2,311 $2,560 Not Implemented
UU0035 # 05 Y:2002 05 2002 RECOVER AND REUSE COOLING WATER $1,491 $1,000 Not Implemented
UU0035 # 04 Y:2002 04 2002 RECOVER WASTE HEAT FROM EQUIPMENT $2,260 $850 Not Implemented
UU0035 # 03 Y:2002 03 2002 INCREASE AMOUNT OF CONDENSATE RETURNED $4,551 $1,225 Not Implemented
UU0035 # 02 Y:2002 02 2002 DIRECT WARMEST AIR TO COMBUSTION INTAKE $678 $900 Not Implemented
OK0638 # 01 Y:2002 01 2002 INSTALL SET-BACK TIMERS $6,131 $0 Not Implemented
OK0638 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,120 $6,442 Implemented
OK0638 # 03 Y:2002 03 2002 INSTALL OCCUPANCY SENSORS $1,798 $862 Implemented
OK0638 # 04 Y:2002 04 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $485 $0 Not Implemented