IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,032

matching recommendations
Reset
SIC 3841 Surgical And Medical Instruments
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0018 # 02 Y:1992 02 1992 INSTALL SPECTRAL REFLECTORS / DELAMP $35,508 $41,505 Implemented
UF0018 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,688 $22,891 Implemented
UF0018 # 04 Y:1992 04 1992 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $34,361 $55,315 Not Implemented
UF0018 # 05 Y:1992 05 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,341 $275 Implemented
UF0018 # 06 Y:1992 06 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,896 $0 Implemented
UF0018 # 07 Y:1992 07 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,038 $7,322 Implemented
UF0018 # 08 Y:1992 08 1992 INSTALL SET-BACK TIMERS $851 $480 Not Implemented
LT0129 # 01 Y:1988 01 1988 INSULATE BARE EQUIPMENT $6,480 $5,500 Implemented
LT0129 # 02 Y:1988 02 1988 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $500 $0 Not Implemented
LT0129 # 03 Y:1988 03 1988 RECOVER WASTE HEAT FROM EQUIPMENT $3,300 $7,900 Not Implemented
LT0129 # 04 Y:1988 04 1988 USE RADIANT HEATER FOR SPOT HEATING $9,900 $5,000 Not Implemented
LT0129 # 05 Y:1988 05 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,520 $5,557 Implemented
LT0129 # 06 Y:1988 06 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,020 $0 Implemented
LT0129 # 07 Y:1988 07 1988 AIR CONDITION ONLY SPACE NECESSARY $6,100 $6,000 Not Implemented
LT0129 # 08 Y:1988 08 1988 INSTALL TIMERS AND/OR THERMOSTATS $590 $600 Not Implemented
LT0129 # 09 Y:1988 09 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $53 $55 Implemented
CO0102 # 01 Y:1987 01 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $825 $200 Implemented
CO0102 # 02 Y:1987 02 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $72 $50 Implemented
CO0102 # 03 Y:1987 03 1987 INSTALL TIMERS AND/OR THERMOSTATS $8,334 $3,600 Implemented
CO0102 # 04 Y:1987 04 1987 OPTIMIZE PLANT POWER FACTOR $3,060 $3,010 Implemented
CO0102 # 05 Y:1987 05 1987 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $139 $450 Implemented
CO0102 # 06 Y:1987 06 1987 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,703 $250 Implemented
CO0102 # 07 Y:1987 07 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $825 $558 Implemented
UD0228 # 01 Y:1987 01 1987 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,352 $13,000 Implemented
UD0228 # 02 Y:1987 02 1987 REDESIGN PROCESS $734 $200 Not Implemented