Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1995
Principal Product Cardiovascular Equipment
NAICS n/a
SIC 3841 - Surgical And Medical Instruments
Sales $100,000,000-$500,000,000
# of Employees 900
Plant Area (Sq.Ft.) 360,000
Annual Production 175,000 Pieces
Production Hrs. Annual 6,240
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $501,549 9,856,976 kWh $0.05
Natural Gas $44,331 11,651 MMBtu $3.80
TOTAL ENERGY COSTS $545,880
RECOMMENDED SAVINGS* $171,380 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $143,340
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$110,140
Cost:
$208,920
$110,140 1,492,087 - - $110,140
1,492,087
kWh
-
-
$
02: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$18,310
Cost:
$55,500
$18,310 480,950 - - $18,310
480,950
kWh
-
-
$
03: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$16,090
Cost:
$42,500
- - $16,090 - -
-
kWh
$16,090
-
$
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$11,370
Cost:
$8,790
$11,370 214,537 - - $11,370
214,537
kWh
-
-
$
05: 2.7252 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM Savings:
$9,950
Cost:
$34,080
$9,950 321,219 - - $9,950
321,219
kWh
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$3,520
Cost:
$4,210
$3,520 77,960 - - $3,520
77,960
kWh
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,000
Cost:
$7,800
$2,000 44,256 - - $2,000
44,256
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$171,380
Cost:
$361,800
$155,290 2,631,009 $16,090 - $155,290
2,631,009
kWh
$16,090
-
$
TOTAL IMPLEMENTED Savings:
$143,340
Cost:
$277,420
$143,340 2,265,534 - - $143,340
2,265,534
kWh
-
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Administrative Changes Electricity Usage Administrative Changes