Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsSIC | 3842 | Surgical Appliances And Supplies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0702 # 07 Y:2000 | 07 | 2000 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $168,000 | $0 | Not Implemented |
GT0702 # 06 Y:2000 | 06 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,350 | $6,700 | Implemented |
GT0702 # 05 Y:2000 | 05 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $34,295 | $82,500 | Not Implemented |
GT0702 # 04 Y:2000 | 04 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,778 | $9,950 | n/a |
GT0702 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,653 | $6,495 | Implemented |
GT0702 # 02 Y:2000 | 02 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $760 | $0 | Not Implemented |
GT0702 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,960 | $350 | Implemented |
GT0551 # 06 Y:1995 | 06 | 1995 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $7,840 | $0 | Not Implemented |
GT0551 # 05 Y:1995 | 05 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $21,276 | $87,727 | Implemented |
GT0551 # 04 Y:1995 | 04 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $34,790 | $16,500 | Implemented |
GT0551 # 03 Y:1995 | 03 | 1995 | INSTALL AUTOMATIC STACK DAMPER | $50,375 | $41,900 | Implemented |
GT0551 # 02 Y:1995 | 02 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $39,160 | $80,000 | Not Implemented |
GT0551 # 01 Y:1995 | 01 | 1995 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $65,795 | $0 | Implemented |
GT0308 # 06 Y:1987 | 06 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,477 | $1,536 | Implemented |
GT0308 # 08 Y:1987 | 08 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $6,325 | $4,000 | Implemented |
GT0308 # 07 Y:1987 | 07 | 1987 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,863 | $6,000 | Not Implemented |
GT0308 # 05 Y:1987 | 05 | 1987 | INSTALL SET-BACK TIMERS | $430 | $0 | Implemented |
GT0308 # 04 Y:1987 | 04 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,395 | $8,935 | Not Implemented |
GT0308 # 03 Y:1987 | 03 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,136 | $3,315 | Implemented |
GT0308 # 02 Y:1987 | 02 | 1987 | TURN OFF EQUIPMENT WHEN NOT IN USE | $952 | $1,200 | Implemented |
GT0308 # 01 Y:1987 | 01 | 1987 | MODIFY TEXTILE DRYERS | $8,658 | $3,400 | Not Implemented |
GT0192 # 03 Y:1983 | 03 | 1983 | INSTALL / REPAIR INSULATION ON STEAM LINES | $130 | $80 | Not Implemented |
GT0192 # 02 Y:1983 | 02 | 1983 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $537 | $800 | Not Implemented |
GT0192 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,025 | $2,450 | Not Implemented |
GT0138 # 01 Y:1982 | 01 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $18,635 | $5,100 | Not Implemented |