Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
632
matching recommendationsSIC | 394 | Toys And Sporting Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0163 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,608 | $0 | Implemented |
AS0163 # 05 Y:1995 | 05 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $595 | $500 | Implemented |
AS0163 # 06 Y:1995 | 06 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,952 | $7,500 | Not Implemented |
AS0163 # 07 Y:1995 | 07 | 1995 | INSULATE BARE EQUIPMENT | $3,121 | $3,655 | Not Implemented |
WI0252 # 01 Y:1995 | 01 | 1995 | INSTALL OCCUPANCY SENSORS | $2,689 | $975 | Not Implemented |
WI0252 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,268 | $6,300 | Not Implemented |
WI0252 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,571 | $2,665 | Not Implemented |
WI0252 # 04 Y:1995 | 04 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $786 | $0 | Implemented |
WI0252 # 05 Y:1995 | 05 | 1995 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,698 | $5,500 | Not Implemented |
WI0252 # 06 Y:1995 | 06 | 1995 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $690 | $1,000 | Not Implemented |
WI0252 # 07 Y:1995 | 07 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $371 | $800 | Not Implemented |
WI0252 # 08 Y:1995 | 08 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $125 | $30 | Implemented |
WI0252 # 09 Y:1995 | 09 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $911 | $4,200 | Not Implemented |
WI0252 # 10 Y:1995 | 10 | 1995 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $543 | $525 | Not Implemented |
SD0116 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $979 | $1,700 | Implemented |
SD0116 # 02 Y:1995 | 02 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $705 | $1,100 | Not Implemented |
SD0116 # 03 Y:1995 | 03 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $211 | $20 | Not Implemented |
SD0116 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,905 | $29,454 | Implemented |
SD0116 # 05 Y:1995 | 05 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $18,871 | $20,540 | Implemented |
SD0116 # 06 Y:1995 | 06 | 1995 | INSTALL OCCUPANCY SENSORS | $2,699 | $3,480 | Not Implemented |
MS0022 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,227 | $6,171 | Implemented |
MS0022 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,855 | $16,900 | Not Implemented |
MS0022 # 03 Y:1995 | 03 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,963 | $0 | Implemented |
MS0022 # 04 Y:1995 | 04 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,414 | $1,500 | Not Implemented |
MS0022 # 05 Y:1995 | 05 | 1995 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $1,209 | $3,900 | Not Implemented |