Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsSIC | 3951 | Pens And Mechanical Pencils |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0441 # 09 Y:2011 | 09 | 2011 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $11,651 | $9,970 | Not Implemented |
UF0441 # 08 Y:2011 | 08 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $23,120 | $7,950 | Not Implemented |
UF0441 # 07 Y:2011 | 07 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $713 | $90 | Not Implemented |
UF0441 # 06 Y:2011 | 06 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $426 | $396 | Not Implemented |
UF0441 # 05 Y:2011 | 05 | 2011 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $10,497 | $4,335 | Not Implemented |
UF0441 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,987 | $4,040 | Not Implemented |
UF0441 # 03 Y:2011 | 03 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,216 | $225 | Not Implemented |
UF0441 # 02 Y:2011 | 02 | 2011 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $8,379 | $5,375 | Not Implemented |
UF0441 # 01 Y:2011 | 01 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,243 | $0 | Not Implemented |
UF0439 # 11 Y:2011 | 11 | 2011 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $140,596 | $3,840 | Not Implemented |
UF0439 # 12 Y:2011 | 12 | 2011 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $7,249 | $4,555 | Not Implemented |
UF0439 # 01 Y:2011 | 01 | 2011 | AIR CONDITION ONLY SPACE NECESSARY | $5,313 | $20,000 | Not Implemented |
UF0439 # 10 Y:2011 | 10 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,063 | $816 | Not Implemented |
UF0439 # 09 Y:2011 | 09 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,007 | $375 | Not Implemented |
UF0439 # 08 Y:2011 | 08 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $8,617 | $500 | Not Implemented |
UF0439 # 07 Y:2011 | 07 | 2011 | USE COMPRESSOR AIR FILTERS | $1,555 | $847 | Implemented |
UF0439 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,983 | $11,500 | Not Implemented |
UF0439 # 05 Y:2011 | 05 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,264 | $2,760 | Not Implemented |
UF0439 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,430 | $4,040 | Implemented |
UF0439 # 03 Y:2011 | 03 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $17,474 | $5,800 | Not Implemented |
UF0439 # 02 Y:2011 | 02 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,289 | $5,193 | Implemented |