Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,432
matching recommendationsSIC | 399 | Miscellaneous Manufactures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0278 # 02 Y:2005 | 02 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,770 | $3,597 | Implemented |
BD0278 # 03 Y:2005 | 03 | 2005 | INSTALL OCCUPANCY SENSORS | $1,527 | $525 | Implemented |
BD0278 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,148 | $2,000 | Implemented |
BD0278 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $552 | $450 | Not Implemented |
BD0278 # 06 Y:2005 | 06 | 2005 | RECOVER AND REUSE COOLING WATER | $1,459 | $5,000 | Implemented |
BD0279 # 01 Y:2005 | 01 | 2005 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $25,688 | $8,400 | Not Implemented |
BD0279 # 02 Y:2005 | 02 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,079 | $3,170 | Not Implemented |
BD0279 # 03 Y:2005 | 03 | 2005 | INSTALL OCCUPANCY SENSORS | $846 | $150 | Not Implemented |
BD0279 # 04 Y:2005 | 04 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $678 | $480 | Not Implemented |
BD0275 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $40,891 | $81,000 | Not Implemented |
BD0275 # 02 Y:2005 | 02 | 2005 | INSTALL REPLACEMENT DOORS | $13,598 | $40,000 | Not Implemented |
BD0275 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,985 | $421 | Implemented |
BD0275 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $5,242 | $3,150 | Implemented |
BD0275 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,674 | $6,000 | Not Implemented |
BD0275 # 06 Y:2005 | 06 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,106 | $6,980 | Implemented |
BD0275 # 07 Y:2005 | 07 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,119 | $6,000 | Implemented |
BD0275 # 08 Y:2005 | 08 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,053 | $470 | Not Implemented |
BD0275 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $391 | $360 | Implemented |
BD0275 # 10 Y:2005 | 10 | 2005 | INSTALL EQUIPMENT TO MOVE PRODUCT | $262,080 | $80,000 | Implemented |
BD0275 # 11 Y:2005 | 11 | 2005 | INSTALL AUTOMATIC PACKING EQUIPMENT | $121,680 | $500,000 | Implemented |
BD0275 # 12 Y:2005 | 12 | 2005 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $67,500 | $2,580 | Implemented |
BD0276 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $27,550 | $24,000 | Not Implemented |
BD0276 # 02 Y:2005 | 02 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $14,544 | $48,000 | Implemented |
BD0276 # 03 Y:2005 | 03 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $8,381 | $2,000 | Not Implemented |
BD0276 # 04 Y:2005 | 04 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,365 | $13,346 | n/a |