IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

15

matching recommendations
Reset
SIC 399 Miscellaneous Manufactures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0410 # 01 Y:1990 01 1990 KEEP LAMPS AND REFLECTORS CLEAN $25,287 $29,907 Implemented
TN0410 # 02 Y:1990 02 1990 INSTALL SET-BACK TIMERS $11,948 $0 Implemented
TN0410 # 03 Y:1990 03 1990 OPTIMIZE PLANT POWER FACTOR $13,343 $44,500 Implemented
TN0410 # 04 Y:1990 04 1990 INSTALL TIMERS AND/OR THERMOSTATS $11,650 $7,440 Not Implemented
TN0410 # 05 Y:1990 05 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $14,844 $930 Implemented
TN0410 # 06 Y:1990 06 1990 INSTALL SET-BACK TIMERS $9,891 $7,200 Not Implemented
TN0410 # 07 Y:1990 07 1990 IMPROVE LUBRICATION PRACTICES $3,261 $0 Not Implemented
TN0410 # 08 Y:1990 08 1990 ADJUST VENTS TO MINIMIZE ENERGY USE $2,515 $3,600 Implemented
TN0410 # 09 Y:1990 09 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,602 $0 Implemented
TN0410 # 10 Y:1990 10 1990 ADJUST VENTS TO MINIMIZE ENERGY USE $975 $1,545 Not Implemented
UD0308 # 01 Y:1990 01 1990 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $13,703 $1,500 Not Implemented
UD0308 # 02 Y:1990 02 1990 TREAT AND REUSE RINSE WATERS $5,588 $2,000 Not Implemented
UD0308 # 03 Y:1990 03 1990 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,831 $0 Not Implemented
UD0308 # 04 Y:1990 04 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,904 $900 Not Implemented
UD0308 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $861 $1,050 Not Implemented