Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsSIC | 399 | Miscellaneous Manufactures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0221 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $20,043 | $0 | Implemented |
SU0221 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,388 | $2,015 | Implemented |
SU0221 # 11 Y:2005 | 11 | 2005 | INSTALL OCCUPANCY SENSORS | $96 | $391 | Implemented |
SU0221 # 06 Y:2005 | 06 | 2005 | INSTALL TURBULATORS | $1,056 | $271 | Not Implemented |
SU0221 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,835 | $444 | Not Implemented |
SU0221 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $129 | $1,155 | Implemented |
SU0221 # 02 Y:2005 | 02 | 2005 | USE SYNTHETIC LUBRICANT | $1,767 | $0 | Implemented |
SU0221 # 08 Y:2005 | 08 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,125 | $5,000 | Not Implemented |
SU0221 # 10 Y:2005 | 10 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $259 | $721 | Implemented |
SU0221 # 03 Y:2005 | 03 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,455 | $0 | Implemented |
SU0221 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $320 | $0 | Implemented |
MS0281 # 09 Y:2005 | 09 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $809 | $0 | Implemented |
MS0281 # 10 Y:2005 | 10 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $782 | $405 | Implemented |
MS0281 # 07 Y:2005 | 07 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,009 | $855 | Implemented |
MS0281 # 03 Y:2005 | 03 | 2005 | INSTALL OCCUPANCY SENSORS | $2,683 | $1,211 | Not Implemented |
MS0281 # 11 Y:2005 | 11 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $444 | $1,485 | Not Implemented |
MS0281 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $1,380 | $243 | Not Implemented |
MS0281 # 02 Y:2005 | 02 | 2005 | COMBINE UTILITY METERS | $12,247 | $0 | Not Implemented |
MS0281 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,603 | $2,508 | Not Implemented |
MS0281 # 01 Y:2005 | 01 | 2005 | BURN A LESS EXPENSIVE GRADE OF FUEL | $79,041 | $295,888 | Not Implemented |
MS0281 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $901 | $176 | Implemented |
MS0281 # 04 Y:2005 | 04 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $2,668 | $800 | Not Implemented |
MS0281 # 12 Y:2005 | 12 | 2005 | USE PHOTOCELL CONTROLS | $405 | $148 | Not Implemented |
MS0281 # 13 Y:2005 | 13 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $371 | $0 | Implemented |
MS0268 # 04 Y:2005 | 04 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,048 | $5,265 | Not Implemented |