Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
16
matching recommendationsSIC | 3996 | Hard Surface Floor Coverings, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0438 # 01 Y:2013 | 01 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $257,500 | $315,000 | Implemented |
BD0438 # 02 Y:2013 | 02 | 2013 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $77,861 | $384,000 | Not Implemented |
BD0438 # 03 Y:2013 | 03 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $63,332 | $57,300 | Implemented |
BD0438 # 04 Y:2013 | 04 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $52,832 | $150,000 | Implemented |
BD0438 # 05 Y:2013 | 05 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $47,432 | $30 | Implemented |
BD0438 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $46,324 | $10,000 | Implemented |
BD0438 # 07 Y:2013 | 07 | 2013 | REPAIR OR REPLACE STEAM TRAPS | $42,432 | $1,600 | Implemented |
BD0438 # 08 Y:2013 | 08 | 2013 | REDUCE EXCESSIVE BOILER BLOWDOWN | $19,230 | $25,000 | Implemented |
BD0438 # 09 Y:2013 | 09 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $27,466 | $20,000 | Implemented |
BD0438 # 10 Y:2013 | 10 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,975 | $34,500 | Implemented |
BD0438 # 11 Y:2013 | 11 | 2013 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $14,811 | $30,000 | Not Implemented |
BD0438 # 12 Y:2013 | 12 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,591 | $25 | Implemented |
BD0438 # 13 Y:2013 | 13 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $10,546 | $30,000 | Implemented |
BD0438 # 14 Y:2013 | 14 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $674 | $550 | Implemented |
BD0438 # 15 Y:2013 | 15 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $286 | $325 | Implemented |
BD0438 # 16 Y:2013 | 16 | 2013 | INSTALL OCCUPANCY SENSORS | $159 | $32 | Implemented |