Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsSIC | 3999 | Manufacturing Industries, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MU0004 # 02 Y:2022 | 02 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,089 | $4,922 | Implemented |
MU0004 # 03 Y:2022 | 03 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $845 | $2,773 | Implemented |
MU0004 # 04 Y:2022 | 04 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $673 | $0 | Not Implemented |
MU0004 # 05 Y:2022 | 05 | 2022 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $250 | $0 | Implemented |
MU0004 # 06 Y:2022 | 06 | 2022 | COMBINE UTILITY METERS | $180 | $0 | Implemented |
MU0004 # 07 Y:2022 | 07 | 2022 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $58 | $77 | Implemented |
MU0004 # 01 Y:2022 | 01 | 2022 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,123 | $0 | Implemented |
UM0410 # 05 Y:2012 | 05 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $682 | $10 | Not Implemented |
UM0410 # 04 Y:2012 | 04 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,438 | $2,000 | Not Implemented |
UM0410 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,779 | $100 | Implemented |
UM0410 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,453 | $11,580 | Not Implemented |
UM0410 # 01 Y:2012 | 01 | 2012 | OPTIMIZE PLANT POWER FACTOR | $7,109 | $20,000 | Not Implemented |
UM0367 # 06 Y:2010 | 06 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $27,997 | $68,395 | Implemented |
UM0367 # 07 Y:2010 | 07 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $17,317 | $9,800 | Implemented |
UM0367 # 08 Y:2010 | 08 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,939 | $500 | Implemented |
UM0367 # 09 Y:2010 | 09 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,537 | $10,500 | Not Implemented |
UM0367 # 10 Y:2010 | 10 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $4,999 | $8,600 | Not Implemented |
UM0367 # 11 Y:2010 | 11 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,186 | $7,500 | Implemented |
UM0367 # 12 Y:2010 | 12 | 2010 | INSULATE BARE EQUIPMENT | $573 | $3,568 | Not Implemented |
UM0367 # 13 Y:2010 | 13 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $277 | $329 | Implemented |
UM0367 # 14 Y:2010 | 14 | 2010 | INSTALL STORM WINDOWS AND DOORS | $171 | $1,400 | Implemented |
UM0367 # 05 Y:2010 | 05 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,497 | $200 | Not Implemented |
UM0367 # 04 Y:2010 | 04 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,913 | $2,000 | Implemented |
UM0367 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,249 | $1,158 | Not Implemented |
UM0367 # 02 Y:2010 | 02 | 2010 | COVER OPEN TANKS | $4,570 | $285 | Not Implemented |