Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

13

matching recommendations
Reset
SIC 495 Sanitary Services
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0419 # 01 Y:2016 01 2016 INSTALL TIMERS AND/OR THERMOSTATS $506 $412 Not Implemented
SU0419 # 02 Y:2016 02 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $246 $190 Not Implemented
SU0419 # 03 Y:2016 03 2016 USE PHOTOCELL CONTROLS $477 $451 Not Implemented
SU0419 # 04 Y:2016 04 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,749 $7,697 Not Implemented
SU0419 # 05 Y:2016 05 2016 REDUCE VENTILATION AIR $491 $899 Not Implemented
SU0307 # 01 Y:2011 01 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,744 $0 Implemented
SU0307 # 02 Y:2011 02 2011 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $2,054 $0 Not Implemented
SU0307 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $323 $97 Implemented
SU0307 # 04 Y:2011 04 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,550 $920 Not Implemented
SU0307 # 05 Y:2011 05 2011 PREHEAT COMBUSTION AIR WITH WASTE HEAT $16,557 $21,257 Implemented
SU0307 # 06 Y:2011 06 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,579 $21,668 Implemented
SU0307 # 07 Y:2011 07 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $139 $287 Not Implemented
SU0307 # 08 Y:2011 08 2011 OPTIMIZE PLANT POWER FACTOR $642 $4,591 Not Implemented