Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
248
matching recommendationsSIC | 51 | Wholesale Tradenondurable Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0105 # 06 Y:2013 | 06 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,400 | $590 | Not Implemented |
DL0105 # 07 Y:2013 | 07 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,200 | $2,300 | Not Implemented |
DL0105 # 08 Y:2013 | 08 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,000 | $80 | Implemented |
DL0105 # 09 Y:2013 | 09 | 2013 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,350 | $3,200 | Not Implemented |
DL0105 # 10 Y:2013 | 10 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $154,000 | $1,000,000 | Implemented |
DL0105 # 11 Y:2013 | 11 | 2013 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $82,900 | $420,000 | Implemented |
LE0361 # 01 Y:2013 | 01 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,204 | $3,144 | Not Implemented |
LE0361 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,773 | $22,500 | Not Implemented |
LE0361 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,705 | $3,219 | Not Implemented |
LE0361 # 04 Y:2013 | 04 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $111,477 | $124,700 | Not Implemented |
LE0361 # 05 Y:2013 | 05 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,891 | $30,200 | Not Implemented |
LE0361 # 06 Y:2013 | 06 | 2013 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $169 | $500 | Not Implemented |
MZ0109 # 01 Y:2013 | 01 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $19,287 | $11,200 | Not Implemented |
MZ0109 # 02 Y:2013 | 02 | 2013 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $14,164 | $10,000 | Not Implemented |
MZ0109 # 03 Y:2013 | 03 | 2013 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $50,867 | $155,000 | Not Implemented |
UK1215 # 01 Y:2013 | 01 | 2013 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $4,249 | $2,200 | Not Implemented |
UK1215 # 02 Y:2013 | 02 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,824 | $4,516 | Implemented |
UK1215 # 03 Y:2013 | 03 | 2013 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $4,021 | $1,610 | Implemented |
UK1215 # 04 Y:2013 | 04 | 2013 | PAY UTILITY BILLS ON TIME | $1,678 | $0 | Implemented |
IC0186 # 01 Y:2011 | 01 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $157 | $0 | n/a |
IC0186 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,790 | $17,297 | n/a |
IC0186 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,133 | $40,382 | n/a |
IC0186 # 04 Y:2011 | 04 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $804 | $2,370 | n/a |
IC0186 # 05 Y:2011 | 05 | 2011 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $1,661 | $7,148 | n/a |
IC0186 # 06 Y:2011 | 06 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $36 | $58 | n/a |