Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
70
matching recommendationsSIC | 769 | Miscellaneous Repair Shops |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0167 # 04 Y:2008 | 04 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $18,032 | $5,700 | Implemented |
MI0167 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,393 | $1,210 | Implemented |
MI0167 # 06 Y:2008 | 06 | 2008 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $7,627 | $15,500 | Implemented |
SF0357 # 08 Y:2008 | 08 | 2008 | SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE | $1,741 | $0 | Not Implemented |
SF0357 # 13 Y:2008 | 13 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,817 | $15,233 | Not Implemented |
SF0357 # 12 Y:2008 | 12 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $8,305 | $25,703 | Not Implemented |
SF0357 # 11 Y:2008 | 11 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,263 | $2,834 | Not Implemented |
SF0357 # 10 Y:2008 | 10 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $3,011 | $294 | Not Implemented |
SF0357 # 09 Y:2008 | 09 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $1,347 | $140 | Not Implemented |
SF0357 # 07 Y:2008 | 07 | 2008 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $1,645 | $6,343 | Not Implemented |
SF0357 # 06 Y:2008 | 06 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $71,962 | $222,664 | Not Implemented |
SF0357 # 05 Y:2008 | 05 | 2008 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $5,290 | $16,144 | Not Implemented |
SF0357 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,858 | $16,291 | Not Implemented |
SF0357 # 03 Y:2008 | 03 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $428 | $728 | Not Implemented |
SF0357 # 02 Y:2008 | 02 | 2008 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $27,148 | $12,102 | Not Implemented |
SF0357 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $4,006 | $0 | Not Implemented |
MA0617 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,016 | $0 | Implemented |
MA0617 # 03 Y:2007 | 03 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,429 | $6,500 | Not Implemented |
MA0617 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,068 | $24,034 | Implemented |
MA0617 # 01 Y:2007 | 01 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $8,579 | $2,348 | Implemented |