Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
482
matching recommendationsSIC | 82 | Educational Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0165 # 02 Y:2020 | 02 | 2020 | REDUCE VENTILATION AIR | $4,090 | $1,125 | Not Implemented |
UU0165 # 03 Y:2020 | 03 | 2020 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,520 | $7,400 | Not Implemented |
UU0165 # 04 Y:2020 | 04 | 2020 | AIR CONDITION ONLY SPACE NECESSARY | $1,220 | $1,500 | Implemented |
UU0165 # 05 Y:2020 | 05 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $660 | $660 | Implemented |
UU0165 # 06 Y:2020 | 06 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $205 | $660 | Not Implemented |
UU0162 # 01 Y:2020 | 01 | 2020 | REDUCE FLUID FLOW RATES | $8,259 | $17,871 | Implemented |
UU0162 # 02 Y:2020 | 02 | 2020 | UPGRADE OBSOLETE EQUIPMENT | $5,390 | $7,024 | Not Implemented |
UU0162 # 03 Y:2020 | 03 | 2020 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,096 | $5,759 | Implemented |
UU0162 # 04 Y:2020 | 04 | 2020 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $328 | $1,141 | Implemented |
BS0123 # 01 Y:2019 | 01 | 2019 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $705 | $2,756 | Not Implemented |
BS0123 # 02 Y:2019 | 02 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $359 | $1,777 | Not Implemented |
BS0123 # 03 Y:2019 | 03 | 2019 | MINIMIZE WATER USAGE | $3,316 | $240 | Not Implemented |
BS0123 # 04 Y:2019 | 04 | 2019 | INSTALL OCCUPANCY SENSORS | $545 | $988 | Not Implemented |
BS0123 # 05 Y:2019 | 05 | 2019 | REDUCE VENTILATION AIR | $5,215 | $2,400 | Not Implemented |
UU0130 # 01 Y:2018 | 01 | 2018 | REDUCE VENTILATION AIR | $13,209 | $0 | Implemented |
UU0130 # 02 Y:2018 | 02 | 2018 | REDUCE VENTILATION AIR | $12,820 | $0 | Implemented |
UU0130 # 03 Y:2018 | 03 | 2018 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $11,365 | $800 | Implemented |
UU0130 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,216 | $11,463 | Implemented |
UU0130 # 05 Y:2018 | 05 | 2018 | INSTALL OCCUPANCY SENSORS | $4,166 | $2,026 | Implemented |
UU0130 # 06 Y:2018 | 06 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,996 | $0 | Implemented |
IP0094 # 01 Y:2018 | 01 | 2018 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $4,035 | $25 | Implemented |
IP0094 # 02 Y:2018 | 02 | 2018 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $346 | $0 | Implemented |
IP0094 # 03 Y:2018 | 03 | 2018 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $10,059 | $1,113 | Not Implemented |
IP0094 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,954 | $94,718 | Implemented |
OK0972 # 01 Y:2017 | 01 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,060 | $26,250 | Not Implemented |