Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
321
matching recommendationsSIC | 821 | Elementary And Secondary Schools |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS2022 # 05 Y:2022 | 05 | 2022 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $1,009 | $1,785 | Implemented |
LS2022 # 06 Y:2022 | 06 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,262 | $13,485 | Implemented |
LS1422 # 01 Y:2022 | 01 | 2022 | INSTALL OCCUPANCY SENSORS | $590 | $200 | Implemented |
LS1422 # 02 Y:2022 | 02 | 2022 | REDUCE HEAT GAIN BY WINDOW TINTING | $7,066 | $2,925 | Not Implemented |
LS1422 # 03 Y:2022 | 03 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,581 | $7,172 | Implemented |
LS1422 # 04 Y:2022 | 04 | 2022 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $5,400 | $11,760 | Not Implemented |
LS1422 # 05 Y:2022 | 05 | 2022 | LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS | $1,392 | $5,200 | Not Implemented |
LS1322 # 01 Y:2022 | 01 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $2,827 | $100 | Implemented |
LS1322 # 02 Y:2022 | 02 | 2022 | INSTALL OCCUPANCY SENSORS | $747 | $375 | Implemented |
LS1322 # 03 Y:2022 | 03 | 2022 | LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS | $5,493 | $3,200 | Not Implemented |
LS1322 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,044 | $31,514 | Implemented |
BS0123 # 01 Y:2019 | 01 | 2019 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $705 | $2,756 | Not Implemented |
BS0123 # 02 Y:2019 | 02 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $359 | $1,777 | Not Implemented |
BS0123 # 03 Y:2019 | 03 | 2019 | MINIMIZE WATER USAGE | $3,316 | $240 | Not Implemented |
BS0123 # 04 Y:2019 | 04 | 2019 | INSTALL OCCUPANCY SENSORS | $545 | $988 | Not Implemented |
BS0123 # 05 Y:2019 | 05 | 2019 | REDUCE VENTILATION AIR | $5,215 | $2,400 | Not Implemented |
OK0972 # 01 Y:2017 | 01 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,060 | $26,250 | Not Implemented |
OK0972 # 02 Y:2017 | 02 | 2017 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,456 | $650 | Implemented |
OK0972 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,025 | $55,774 | Not Implemented |
OK0972 # 04 Y:2017 | 04 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $15,938 | $27,750 | Not Implemented |
OK0972 # 05 Y:2017 | 05 | 2017 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $3,380 | $1,500 | Implemented |
OK0972 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,158 | $47,096 | Not Implemented |
TT0174 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,076 | $107,370 | Implemented |
TT0174 # 02 Y:2016 | 02 | 2016 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $9,274 | $57,890 | Not Implemented |
TT0174 # 03 Y:2016 | 03 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,205 | $7,000 | Not Implemented |