Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
117
matching recommendationsSIC | 8211 | Elementary And Secondary Schools |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MUCM21 # 01 Y:2024 | 01 | 2024 | USE PHOTOCELL CONTROLS | $348 | $139 | Not Implemented |
MUCM21 # 02 Y:2024 | 02 | 2024 | INSTALL OCCUPANCY SENSORS | $3,650 | $284 | Not Implemented |
MUCM21 # 03 Y:2024 | 03 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,996 | $4,883 | Not Implemented |
MUCM21 # 04 Y:2024 | 04 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $19,687 | $183,595 | Not Implemented |
LS1024 # 02 Y:2024 | 02 | 2024 | TURN OFF EQUIPMENT WHEN NOT IN USE | $343 | $0 | Implemented |
LS1024 # 03 Y:2024 | 03 | 2024 | INSTALL OCCUPANCY SENSORS | $2,423 | $875 | Not Implemented |
LS1024 # 04 Y:2024 | 04 | 2024 | REDUCE HEAT GAIN BY WINDOW TINTING | $1,635 | $2,352 | Not Implemented |
LS1024 # 01 Y:2024 | 01 | 2024 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,372 | $0 | Implemented |
MUCM23 # 10 Y:2024 | 10 | 2024 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,017 | $0 | Not Implemented |
MUCM23 # 09 Y:2024 | 09 | 2024 | COMBINE UTILITY METERS | $119 | $0 | Not Implemented |
MUCM23 # 08 Y:2024 | 08 | 2024 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $5,208 | $0 | Not Implemented |
MUCM23 # 07 Y:2024 | 07 | 2024 | INSTALL TIMERS AND/OR THERMOSTATS | $23,125 | $1,830 | Not Implemented |
MUCM23 # 06 Y:2024 | 06 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,898 | $0 | Implemented |
MUCM23 # 05 Y:2024 | 05 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14 | $32 | Implemented |
MUCM23 # 04 Y:2024 | 04 | 2024 | INSTALL OCCUPANCY SENSORS | $1,319 | $3,640 | Implemented |
MUCM23 # 03 Y:2024 | 03 | 2024 | TURN OFF EQUIPMENT WHEN NOT IN USE | $58 | $0 | Implemented |
MUCM23 # 02 Y:2024 | 02 | 2024 | KEEP EQUIPMENT CLEAN | $89 | $0 | Implemented |
MUCM23 # 01 Y:2024 | 01 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,246 | $3,407 | Implemented |
LS1024 # 05 Y:2024 | 05 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,551 | $5,440 | Implemented |
MUCM22 # 08 Y:2024 | 08 | 2024 | MINIMIZE WATER USAGE | $3,394 | $23,705 | Not Implemented |
MUCM22 # 01 Y:2024 | 01 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,932 | $1,165 | Not Implemented |
MUCM22 # 03 Y:2024 | 03 | 2024 | INSTALL OCCUPANCY SENSORS | $3,716 | $2,058 | Not Implemented |
MUCM22 # 07 Y:2024 | 07 | 2024 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $284 | $1,021 | Not Implemented |
MUCM22 # 06 Y:2024 | 06 | 2024 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $67 | $270 | Not Implemented |
MUCM22 # 04 Y:2024 | 04 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,942 | $3,096 | Not Implemented |