Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
110
matching recommendationsSIC | 87 | Engineering & Management Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0398 # 03 Y:2022 | 03 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,341 | $3,593 | Not Implemented |
MS0398 # 02 Y:2022 | 02 | 2022 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $8,148 | $536 | Not Implemented |
MS0398 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,227 | $6,769 | Implemented |
LS1622 # 03 Y:2022 | 03 | 2022 | INSTALL OCCUPANCY SENSORS | $250 | $200 | Not Implemented |
LS1622 # 01 Y:2022 | 01 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $3,718 | $350 | Implemented |
LS1622 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,928 | $6,120 | Implemented |
LS1622 # 02 Y:2022 | 02 | 2022 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $3,014 | $1,496 | Not Implemented |
LS1522 # 05 Y:2022 | 05 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $872 | $4,215 | Not Implemented |
LS1522 # 04 Y:2022 | 04 | 2022 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $702 | $1,050 | Not Implemented |
LS1522 # 03 Y:2022 | 03 | 2022 | INSTALL OCCUPANCY SENSORS | $3,599 | $4,375 | Not Implemented |
LS1522 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,079 | $33,425 | Implemented |
LS1522 # 01 Y:2022 | 01 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $59,902 | $3,750 | Implemented |
MS0395 # 03 Y:2022 | 03 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $677 | $540 | Implemented |
MS0395 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,723 | $18,748 | Implemented |
MS0395 # 04 Y:2022 | 04 | 2022 | UPGRADE OBSOLETE EQUIPMENT | $2,447 | $15,480 | Not Implemented |
MS0395 # 01 Y:2022 | 01 | 2022 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,342 | $210,000 | Not Implemented |
OR0723 # 03 Y:2019 | 03 | 2019 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $5,360 | $1,789 | Implemented |
OR0723 # 02 Y:2019 | 02 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,541 | $1,027 | Not Implemented |
OR0723 # 01 Y:2019 | 01 | 2019 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $488,033 | $1,500,000 | Implemented |
WM0104 # 01 Y:2017 | 01 | 2017 | STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS | $64,540 | $93,226 | Not Implemented |
WM0104 # 04 Y:2017 | 04 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,736 | $45,000 | Not Implemented |
WM0104 # 05 Y:2017 | 05 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,008 | $0 | Implemented |
WM0104 # 07 Y:2017 | 07 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,589 | $554 | Not Implemented |
WM0104 # 06 Y:2017 | 06 | 2017 | USE SYNTHETIC LUBRICANT | $7,607 | $650 | Not Implemented |
WM0104 # 03 Y:2017 | 03 | 2017 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $14,165 | $0 | Implemented |