Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

67,037

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LT0142 # 04 Y:1989 04 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,470 $400 Implemented
LT0142 # 05 Y:1989 05 1989 INSTALL TIMERS AND/OR THERMOSTATS $3,092 $200 Implemented
LT0142 # 07 Y:1989 07 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $423 $100 Implemented
LT0142 # 08 Y:1989 08 1989 REPAIR AND ELIMINATE STEAM LEAKS $3,193 $224 Implemented
MA0136 # 01 Y:1989 01 1989 INSTALL SET-BACK TIMERS $422 $892 Implemented
MA0136 # 03 Y:1989 03 1989 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,017 $1,400 Implemented
MA0142 # 01 Y:1989 01 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $16,859 $570 Implemented
MA0142 # 06 Y:1989 06 1989 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $27,100 $13,000 Implemented
MA0142 # 07 Y:1989 07 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $52,700 $680 Implemented
KU0271 # 02 Y:1989 02 1989 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $5,826 $297 Implemented
KU0271 # 03 Y:1989 03 1989 KEEP BOILER TUBES CLEAN $5,300 $1,500 Implemented
KU0271 # 07 Y:1989 07 1989 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,406 $100 Implemented
KU0271 # 08 Y:1989 08 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,370 $7,134 Implemented
KU0271 # 09 Y:1989 09 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,445 $1,500 Implemented
KU0272 # 02 Y:1989 02 1989 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $1,242 $300 Implemented
KU0272 # 06 Y:1989 06 1989 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,254 $250 Implemented
KU0272 # 07 Y:1989 07 1989 REPAIR AND ELIMINATE STEAM LEAKS $18,354 $3,000 Implemented
KU0272 # 08 Y:1989 08 1989 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $59,852 $0 Implemented
WI0046 # 01 Y:1989 01 1989 IMPROVE LUBRICATION PRACTICES $2,686 $0 Implemented
WI0046 # 03 Y:1989 03 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $284 $540 Implemented
WI0046 # 05 Y:1989 05 1989 TURN OFF EQUIPMENT WHEN NOT IN USE $463 $1,300 Implemented
WI0047 # 01 Y:1989 01 1989 IMPROVE LUBRICATION PRACTICES $3,210 $500 Implemented
WI0047 # 02 Y:1989 02 1989 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $3,901 $1,300 Implemented
WI0047 # 03 Y:1989 03 1989 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $238 $0 Implemented
WI0047 # 05 Y:1989 05 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $9,913 $3,600 Implemented