Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
67,016
matching recommendationsARC | 2 | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0055 # 01 Y:1986 | 01 | 1986 | IMPROVE LUBRICATION PRACTICES | $2,355 | $0 | Implemented |
CO0055 # 02 Y:1986 | 02 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,336 | $300 | Implemented |
CO0055 # 03 Y:1986 | 03 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,244 | $600 | Implemented |
CO0055 # 05 Y:1986 | 05 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $417 | $150 | Implemented |
CO0055 # 06 Y:1986 | 06 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $533 | $300 | Implemented |
CO0055 # 07 Y:1986 | 07 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,802 | $200 | Implemented |
CO0055 # 08 Y:1986 | 08 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $242 | $400 | Implemented |
CO0055 # 10 Y:1986 | 10 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,539 | $1,293 | Implemented |
AT0034 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $264 | $195 | Implemented |
AT0034 # 02 Y:1986 | 02 | 1986 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $4,201 | $2,000 | Implemented |
AT0034 # 03 Y:1986 | 03 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,806 | $900 | Implemented |
AT0034 # 04 Y:1986 | 04 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,213 | $1,000 | Implemented |
AT0034 # 05 Y:1986 | 05 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $303 | $50 | Implemented |
AT0034 # 06 Y:1986 | 06 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $268 | $250 | Implemented |
AT0034 # 07 Y:1986 | 07 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $90 | $163 | Implemented |
AT0034 # 08 Y:1986 | 08 | 1986 | INCREASE AMOUNT OF CONDENSATE RETURNED | $4,997 | $5,000 | Implemented |
TN0269 # 01 Y:1986 | 01 | 1986 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $2,310 | $1,500 | Implemented |
TN0269 # 02 Y:1986 | 02 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,414 | $1,800 | Implemented |
TN0269 # 03 Y:1986 | 03 | 1986 | INSTALL SET-BACK TIMERS | $2,001 | $0 | Implemented |
TN0269 # 04 Y:1986 | 04 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $680 | $0 | Implemented |
TN0269 # 05 Y:1986 | 05 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $920 | $288 | Implemented |
TN0270 # 01 Y:1986 | 01 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,709 | $15,000 | Implemented |
TN0270 # 02 Y:1986 | 02 | 1986 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $2,686 | $1,200 | Implemented |
TN0270 # 03 Y:1986 | 03 | 1986 | USE MINIMUM STEAM OPERATING PRESSURE | $271 | $0 | Implemented |
TN0270 # 04 Y:1986 | 04 | 1986 | INSTALL SET-BACK TIMERS | $680 | $0 | Implemented |