Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
316
matching recommendationsARC | 2 | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0064 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,486 | $2,126 | Implemented |
UD0058 # 04 Y:1982 | 04 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,600 | $4,500 | Implemented |
UD0064 # 01 Y:1982 | 01 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $12,885 | $11,043 | Implemented |
UD0060 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,603 | $4,366 | Implemented |
OK0063 # 03 Y:1982 | 03 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $106 | $205 | Implemented |
UD0060 # 04 Y:1982 | 04 | 1982 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,230 | $46,000 | Implemented |
UD0063 # 04 Y:1982 | 04 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $29,194 | $42,215 | Implemented |
UD0067 # 05 Y:1982 | 05 | 1982 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,207 | $286 | Implemented |
UD0063 # 03 Y:1982 | 03 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,592 | $61 | Implemented |
UD0060 # 02 Y:1982 | 02 | 1982 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,089 | $1,000 | Implemented |
UD0067 # 02 Y:1982 | 02 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $12,896 | $64,600 | Implemented |
GT0151 # 02 Y:1982 | 02 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $42,062 | $0 | Implemented |
GT0151 # 03 Y:1982 | 03 | 1982 | KEEP BOILER TUBES CLEAN | $20,627 | $500 | Implemented |
OK0058 # 03 Y:1982 | 03 | 1982 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $194 | $475 | Implemented |
UD0060 # 05 Y:1982 | 05 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $618 | $0 | Implemented |
UD0067 # 01 Y:1982 | 01 | 1982 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,431 | $250 | Implemented |
UD0064 # 04 Y:1982 | 04 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,281 | $2,200 | Implemented |
OK0058 # 04 Y:1982 | 04 | 1982 | USE UTILITY CONTROLLED POWER MANAGEMENT | $365 | $0 | Implemented |
UD0067 # 04 Y:1982 | 04 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,770 | $0 | Implemented |
UD0058 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,729 | $2,704 | Implemented |
UD0067 # 03 Y:1982 | 03 | 1982 | INSTALL STORM WINDOWS AND DOORS | $6,999 | $7,642 | Implemented |
UD0061 # 02 Y:1982 | 02 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $72 | $0 | Implemented |
OK0058 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $261 | $270 | Implemented |
UD0054 # 03 Y:1982 | 03 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,264 | $8,000 | Implemented |
UD0054 # 04 Y:1982 | 04 | 1982 | INSTALL STORM WINDOWS AND DOORS | $20,425 | $29,798 | Implemented |