Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,041

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0391 # 09 Y:1993 09 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $100 $88 Implemented
TN0479 # 02 Y:1993 02 1993 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $418 $720 Implemented
UF0050 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,876 $1,499 Implemented
UF0050 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,217 $3,011 Implemented
UF0050 # 05 Y:1993 05 1993 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $540 $300 Implemented
UF0050 # 06 Y:1993 06 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,792 $4,698 Implemented
UF0050 # 07 Y:1993 07 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $528 $300 Implemented
UF0050 # 09 Y:1993 09 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,657 $550 Implemented
OK0395 # 01 Y:1993 01 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,066 $1,500 Implemented
OK0395 # 04 Y:1993 04 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,655 $0 Implemented
IA0044 # 02 Y:1993 02 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,209 $630 Implemented
IA0044 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,777 $5,800 Implemented
IA0044 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $739 $73 Implemented
IA0044 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $125 $240 Implemented
UD0391 # 01 Y:1993 01 1993 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $16,524 $0 Implemented
UD0391 # 02 Y:1993 02 1993 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $17,952 $0 Implemented
UD0391 # 03 Y:1993 03 1993 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,596 $0 Implemented
UD0391 # 05 Y:1993 05 1993 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $527 $550 Implemented
TN0487 # 01 Y:1993 01 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,905 $1,320 Implemented
TN0487 # 04 Y:1993 04 1993 USE SYNTHETIC LUBRICANT $114 $0 Implemented
WI0166 # 01 Y:1993 01 1993 CONSIDER THREE OR FOUR DAYS AROUND-THE-CLOCK OPERATION RATHER THAN ONE OR TWO SHIFTS PER DAY $1,244 $0 Implemented
WI0166 # 02 Y:1993 02 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,344 $1,560 Implemented
WI0166 # 03 Y:1993 03 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $1,023 $0 Implemented
UF0048 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,828 $824 Implemented
UF0048 # 03 Y:1993 03 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,113 $20,642 Implemented