Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

147,181

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0168 # 04 Y:1993 04 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $5,200 $1,152 Implemented
OR0168 # 05 Y:1993 05 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $378 $1,008 Implemented
OR0168 # 06 Y:1993 06 1993 KEEP BOILER TUBES CLEAN $351 $1,000 Implemented
WI0170 # 01 Y:1993 01 1993 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,669 $800 Implemented
WI0170 # 02 Y:1993 02 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,102 $650 Implemented
WI0170 # 03 Y:1993 03 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,042 $0 Not Implemented
WI0170 # 04 Y:1993 04 1993 INSTALL OCCUPANCY SENSORS $171 $600 Not Implemented
WI0170 # 05 Y:1993 05 1993 RECOVER MECHANICAL ENERGY $740 $725 Not Implemented
WI0170 # 06 Y:1993 06 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $126 $0 Not Implemented
WI0170 # 07 Y:1993 07 1993 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $319 $0 Not Implemented
WI0170 # 08 Y:1993 08 1993 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $304 $800 Not Implemented
WI0170 # 09 Y:1993 09 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $295 $640 Not Implemented
UF0054 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,727 $3,429 Implemented
UF0054 # 02 Y:1993 02 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $13,230 $26,355 Not Implemented
UF0054 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,585 $4,022 Not Implemented
UF0054 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $72 $30 Not Implemented
UF0054 # 05 Y:1993 05 1993 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $14,700 $22,000 Implemented
UF0054 # 06 Y:1993 06 1993 REPLACE ELECTRIC REHEAT WITH HEAT PIPES $11,340 $7,000 Not Implemented
UF0054 # 07 Y:1993 07 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $595 $150 Not Implemented
UF0054 # 08 Y:1993 08 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $8,470 $10,400 Not Implemented
MO0078 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,594 $17,057 Implemented
MO0078 # 02 Y:1993 02 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $247 $570 Not Implemented
MO0078 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,239 $963 Not Implemented
MO0078 # 04 Y:1993 04 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,688 $100 Not Implemented
MO0078 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,881 $30,661 Implemented