Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,390
matching recommendationsARC | 2. | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0240 # 05 Y:1985 | 05 | 1985 | USE MINIMUM SAFE OVEN VENTILATION | $780 | $0 | Implemented |
GT0240 # 06 Y:1985 | 06 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $7,420 | $5,000 | Implemented |
GT0241 # 01 Y:1985 | 01 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,960 | $3,000 | Implemented |
GT0241 # 02 Y:1985 | 02 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $453 | $257 | Implemented |
GT0241 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,400 | $26,000 | Implemented |
GT0241 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $836 | $123 | Implemented |
GT0241 # 05 Y:1985 | 05 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,430 | $4,000 | Implemented |
MA0013 # 01 Y:1985 | 01 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $949 | $171 | Implemented |
MA0013 # 02 Y:1985 | 02 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,976 | $8,800 | Implemented |
MA0013 # 04 Y:1985 | 04 | 1985 | DISCONNECT BALLASTS | $1,543 | $900 | Implemented |
MA0014 # 01 Y:1985 | 01 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $8,022 | $2,622 | Implemented |
MA0014 # 03 Y:1985 | 03 | 1985 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $329 | $186 | Implemented |
MA0014 # 04 Y:1985 | 04 | 1985 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $9,947 | $3,050 | Implemented |
OK0156 # 02 Y:1985 | 02 | 1985 | OPTIMIZE PLANT POWER FACTOR | $5,639 | $7,640 | Implemented |
OK0156 # 05 Y:1985 | 05 | 1985 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,307 | $624 | Implemented |
OK0156 # 10 Y:1985 | 10 | 1985 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,411 | $0 | Implemented |
OK0156 # 11 Y:1985 | 11 | 1985 | INSULATE BARE EQUIPMENT | $290 | $880 | Implemented |
TS0008 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,670 | $588 | Implemented |
TS0010 # 01 Y:1985 | 01 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,024 | $1,500 | Implemented |
TS0010 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $876 | $94 | Implemented |
TS0010 # 03 Y:1985 | 03 | 1985 | REDUCE VENTILATION AIR | $4,602 | $460 | Implemented |
TS0010 # 04 Y:1985 | 04 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $158 | $25 | Implemented |
TS0012 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $952 | $30 | Implemented |
TS0012 # 03 Y:1985 | 03 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,907 | $0 | Implemented |
TS0012 # 04 Y:1985 | 04 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,998 | $9,765 | Implemented |