Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,139

matching recommendations
Reset
ARC 2. ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0346 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,423 $19,322 Not Implemented
UM0346 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,497 $0 Not Implemented
UM0346 # 04 Y:2008 04 2008 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,161 $3,500 Not Implemented
UM0346 # 05 Y:2008 05 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,880 $515 Not Implemented
UM0346 # 06 Y:2008 06 2008 INSTALL OCCUPANCY SENSORS $1,706 $2,484 Not Implemented
UM0346 # 07 Y:2008 07 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $1,361 $580 Not Implemented
UM0346 # 08 Y:2008 08 2008 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,284 $0 Not Implemented
UM0346 # 09 Y:2008 09 2008 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $548 $280 Not Implemented
UM0346 # 01 Y:2008 01 2008 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $10,849 $500 Not Implemented
DL0025 # 01 Y:2008 01 2008 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $1,078 $0 Not Implemented
DL0025 # 02 Y:2008 02 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,976 $0 Implemented
DL0025 # 03 Y:2008 03 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $36,900 $0 Implemented
DL0025 # 04 Y:2008 04 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,600 $0 Not Implemented
DL0025 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,919 $30,000 Implemented
DL0025 # 06 Y:2008 06 2008 UPGRADE CONTROLS ON COMPRESSORS $3,964 $0 Not Implemented
MS0335 # 01 Y:2008 01 2008 REPAIR AND ELIMINATE STEAM LEAKS $38,137 $280 Not Implemented
MS0335 # 02 Y:2008 02 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $24,959 $7,500 Not Implemented
MS0335 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $43,147 $30,570 Implemented
MS0335 # 04 Y:2008 04 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $17,965 $34,830 Not Implemented
MS0335 # 05 Y:2008 05 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,037 $389 Implemented
MS0335 # 06 Y:2008 06 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,045 $8,725 Implemented
MS0335 # 07 Y:2008 07 2008 INSTALL OCCUPANCY SENSORS $1,338 $13,840 Not Implemented
MS0335 # 08 Y:2008 08 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,515 $476 Not Implemented
UM0345 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,365 $7,499 Not Implemented
UM0345 # 02 Y:2008 02 2008 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $8,397 $1,650 Implemented