Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,411
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0025 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,122 | $1,456 | Implemented |
AR0025 # 03 Y:1994 | 03 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,184 | $725 | Implemented |
AR0025 # 04 Y:1994 | 04 | 1994 | REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE | $107,965 | $66,000 | Not Implemented |
AR0025 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,343 | $9,530 | Implemented |
AR0025 # 06 Y:1994 | 06 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,863 | $600 | Implemented |
AR0024 # 01 Y:1994 | 01 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $9,495 | $210 | Implemented |
AR0024 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $798 | $974 | Implemented |
AR0024 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,118 | $1,349 | Implemented |
AR0024 # 04 Y:1994 | 04 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $154 | $50 | Implemented |
AR0024 # 05 Y:1994 | 05 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,986 | $0 | Implemented |
AR0024 # 06 Y:1994 | 06 | 1994 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $724 | $0 | Implemented |
AR0022 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,415 | $5,110 | Not Implemented |
AR0022 # 02 Y:1994 | 02 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,133 | $420 | Not Implemented |
AR0022 # 03 Y:1994 | 03 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,129 | $2,544 | Not Implemented |
AR0022 # 04 Y:1994 | 04 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,867 | $1,000 | Not Implemented |
AR0022 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $756 | $243 | Not Implemented |
AR0023 # 01 Y:1994 | 01 | 1994 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,012 | $0 | Implemented |
AR0023 # 02 Y:1994 | 02 | 1994 | REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE | $101,949 | $59,000 | Not Implemented |
AR0023 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $12,592 | $20,205 | Implemented |
AR0023 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,010 | $8,910 | Implemented |
AR0021 # 01 Y:1994 | 01 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $16,260 | $6,000 | Implemented |
AR0021 # 02 Y:1994 | 02 | 1994 | USE OPTIMUM THICKNESS INSULATION | $855 | $100 | Implemented |
AR0021 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $20,139 | $9,600 | Implemented |
AR0021 # 04 Y:1994 | 04 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,558 | $150 | Implemented |
AR0021 # 05 Y:1994 | 05 | 1994 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $3,017 | $5,760 | Implemented |