IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,391

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0016 # 03 Y:1995 03 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,583 $3,000 n/a
BD0016 # 04 Y:1995 04 1995 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $1,362 $5,900 n/a
BD0015 # 01 Y:1994 01 1994 INSTALL OCCUPANCY SENSORS $1,977 $1,050 Implemented
BD0015 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,917 $1,240 Not Implemented
BD0015 # 03 Y:1994 03 1994 USE POWER DURING OFF-PEAK PERIODS $2,626 $20 Not Implemented
BD0015 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $430 $250 Implemented
BD0015 # 05 Y:1994 05 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,248 $20 Implemented
BD0015 # 06 Y:1994 06 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,008 $13,640 Implemented
BD0015 # 07 Y:1994 07 1994 INSULATE BARE EQUIPMENT $8,896 $4,930 Implemented
BD0014 # 01 Y:1994 01 1994 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $206,117 $508,700 Not Implemented
BD0014 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,879 $7,000 Not Implemented
BD0014 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $22,398 $33,500 Implemented
BD0014 # 04 Y:1994 04 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,051 $20 Implemented
BD0014 # 05 Y:1994 05 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,150 $500 Implemented
BD0014 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,866 $2,342 Implemented
BD0014 # 07 Y:1994 07 1994 INSTALL OCCUPANCY SENSORS $2,169 $1,000 Not Implemented
BD0013 # 01 Y:1994 01 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,745 $2,250 Not Implemented
BD0013 # 02 Y:1994 02 1994 RECOVER WASTE HEAT FROM EQUIPMENT $7,926 $100 Not Implemented
BD0013 # 03 Y:1994 03 1994 RECOVER AND REUSE COOLING WATER $1,975 $5,000 Not Implemented
BD0013 # 04 Y:1994 04 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,553 $13,640 Not Implemented
BD0013 # 05 Y:1994 05 1994 INSTALL TURBULATORS $1,003 $2,400 Not Implemented
BD0013 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,835 $13,008 Not Implemented
BD0012 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $35,731 $74,007 Implemented
BD0012 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $501 $500 Implemented
BD0012 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,853 $6,580 Implemented