Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,391
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0282 # 06 Y:2005 | 06 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,439 | $3,200 | Not Implemented |
BD0282 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $1,696 | $375 | Not Implemented |
BD0282 # 08 Y:2005 | 08 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,494 | $3,200 | Not Implemented |
BD0282 # 09 Y:2005 | 09 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $544 | $0 | Not Implemented |
BD0282 # 10 Y:2005 | 10 | 2005 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $212 | $450 | Not Implemented |
BD0280 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $34,711 | $34,000 | Not Implemented |
BD0280 # 02 Y:2005 | 02 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $30,129 | $31,500 | Not Implemented |
BD0280 # 03 Y:2005 | 03 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $13,187 | $1,000 | Not Implemented |
BD0280 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $10,565 | $5,850 | Implemented |
BD0280 # 05 Y:2005 | 05 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,110 | $1,000 | Implemented |
BD0280 # 06 Y:2005 | 06 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,694 | $9,500 | Not Implemented |
BD0280 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,514 | $1,400 | Implemented |
BD0280 # 08 Y:2005 | 08 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $3,413 | $2,000 | Implemented |
BD0280 # 09 Y:2005 | 09 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,944 | $0 | Implemented |
BD0280 # 10 Y:2005 | 10 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $708 | $750 | Not Implemented |
BD0278 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $4,205 | $16,000 | Implemented |
BD0278 # 02 Y:2005 | 02 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,770 | $3,597 | Implemented |
BD0278 # 03 Y:2005 | 03 | 2005 | INSTALL OCCUPANCY SENSORS | $1,527 | $525 | Implemented |
BD0278 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,148 | $2,000 | Implemented |
BD0278 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $552 | $450 | Not Implemented |
BD0278 # 06 Y:2005 | 06 | 2005 | RECOVER AND REUSE COOLING WATER | $1,459 | $5,000 | Implemented |
BD0279 # 01 Y:2005 | 01 | 2005 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $25,688 | $8,400 | Not Implemented |
BD0279 # 02 Y:2005 | 02 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,079 | $3,170 | Not Implemented |
BD0279 # 03 Y:2005 | 03 | 2005 | INSTALL OCCUPANCY SENSORS | $846 | $150 | Not Implemented |
BD0279 # 04 Y:2005 | 04 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $678 | $480 | Not Implemented |