Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,456
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0054 # 10 Y:1986 | 10 | 1986 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $4,405 | $1,500 | Not Implemented |
CO0054 # 11 Y:1986 | 11 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,919 | $90 | Implemented |
CO0055 # 01 Y:1986 | 01 | 1986 | IMPROVE LUBRICATION PRACTICES | $2,355 | $0 | Implemented |
CO0055 # 02 Y:1986 | 02 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,336 | $300 | Implemented |
CO0055 # 03 Y:1986 | 03 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,244 | $600 | Implemented |
CO0055 # 04 Y:1986 | 04 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,716 | $400 | Not Implemented |
CO0055 # 05 Y:1986 | 05 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $417 | $150 | Implemented |
CO0055 # 06 Y:1986 | 06 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $533 | $300 | Implemented |
CO0055 # 07 Y:1986 | 07 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,802 | $200 | Implemented |
CO0055 # 08 Y:1986 | 08 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $242 | $400 | Implemented |
CO0055 # 09 Y:1986 | 09 | 1986 | REDUCE GLAZED AREAS IN BUILDINGS | $76 | $75 | Not Implemented |
CO0055 # 10 Y:1986 | 10 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,539 | $1,293 | Implemented |
CO0051 # 01 Y:1986 | 01 | 1986 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,958 | $500 | Not Implemented |
CO0051 # 02 Y:1986 | 02 | 1986 | AIR CONDITION ONLY SPACE NECESSARY | $809 | $500 | Not Implemented |
CO0051 # 03 Y:1986 | 03 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,508 | $177 | Not Implemented |
CO0051 # 04 Y:1986 | 04 | 1986 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,552 | $190 | Not Implemented |
CO0051 # 05 Y:1986 | 05 | 1986 | IMPROVE LUBRICATION PRACTICES | $1,043 | $0 | Not Implemented |
CO0051 # 06 Y:1986 | 06 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $578 | $200 | Not Implemented |
CO0051 # 07 Y:1986 | 07 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $189 | $280 | Not Implemented |
CO0051 # 08 Y:1986 | 08 | 1986 | TURN OFF EQUIPMENT WHEN NOT IN USE | $80 | $100 | Not Implemented |
CO0051 # 09 Y:1986 | 09 | 1986 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $305 | $400 | Not Implemented |
CO0051 # 10 Y:1986 | 10 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,412 | $476 | Not Implemented |
CO0052 # 01 Y:1986 | 01 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,900 | $300 | Implemented |
CO0052 # 02 Y:1986 | 02 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,221 | $2,500 | Implemented |
CO0052 # 03 Y:1986 | 03 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $763 | $1,500 | Implemented |