IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,456

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0054 # 10 Y:1986 10 1986 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $4,405 $1,500 Not Implemented
CO0054 # 11 Y:1986 11 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,919 $90 Implemented
CO0055 # 01 Y:1986 01 1986 IMPROVE LUBRICATION PRACTICES $2,355 $0 Implemented
CO0055 # 02 Y:1986 02 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,336 $300 Implemented
CO0055 # 03 Y:1986 03 1986 RECOVER WASTE HEAT FROM EQUIPMENT $2,244 $600 Implemented
CO0055 # 04 Y:1986 04 1986 RECOVER WASTE HEAT FROM EQUIPMENT $1,716 $400 Not Implemented
CO0055 # 05 Y:1986 05 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $417 $150 Implemented
CO0055 # 06 Y:1986 06 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $533 $300 Implemented
CO0055 # 07 Y:1986 07 1986 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,802 $200 Implemented
CO0055 # 08 Y:1986 08 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $242 $400 Implemented
CO0055 # 09 Y:1986 09 1986 REDUCE GLAZED AREAS IN BUILDINGS $76 $75 Not Implemented
CO0055 # 10 Y:1986 10 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,539 $1,293 Implemented
CO0051 # 01 Y:1986 01 1986 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,958 $500 Not Implemented
CO0051 # 02 Y:1986 02 1986 AIR CONDITION ONLY SPACE NECESSARY $809 $500 Not Implemented
CO0051 # 03 Y:1986 03 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,508 $177 Not Implemented
CO0051 # 04 Y:1986 04 1986 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,552 $190 Not Implemented
CO0051 # 05 Y:1986 05 1986 IMPROVE LUBRICATION PRACTICES $1,043 $0 Not Implemented
CO0051 # 06 Y:1986 06 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $578 $200 Not Implemented
CO0051 # 07 Y:1986 07 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $189 $280 Not Implemented
CO0051 # 08 Y:1986 08 1986 TURN OFF EQUIPMENT WHEN NOT IN USE $80 $100 Not Implemented
CO0051 # 09 Y:1986 09 1986 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS $305 $400 Not Implemented
CO0051 # 10 Y:1986 10 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,412 $476 Not Implemented
CO0052 # 01 Y:1986 01 1986 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,900 $300 Implemented
CO0052 # 02 Y:1986 02 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,221 $2,500 Implemented
CO0052 # 03 Y:1986 03 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $763 $1,500 Implemented